1. Power Requirements
The SL Pa rBlazer 100 UV Luminaire operates on AC input voltages from 100 to 240 VAC.
WARN ING! The SL ParBlazer 100 UV luminaire does not have an ON/OFF switch. Always disconnect power input cable
to completely remove power from the luminaire when not in use.
AC Power Operation
When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire
contains an auto-ranging power supply. Each luminaire can draw up to 100 Watts.
WARN ING! Maximum amount of fixtures that may be daisy-chained is (A) 10 units 100 ~ 120VAC or (B) 23 units
230 ~ 240VAC (15 Amps).
Note: For wiring of AC input connector, refer to
"Connecting SL ParBlazer 100 UV to AC Power" on page 6
.
2. Connecting Power
Units can be powered in one of two ways:
Direct connection to an AC power source using an AC input cable. For wiring
of the AC input connector
,
refer
to
Connection from the AC output of another SL
ParBlaz er 100 UV. When using this method, it is very important not
to connect any other type of equipment device.
WARN ING
! Only connect other SL ParBlazer 100 UV luminaires to the AC Output (Thru) connector of an
Installation & User’s Manual
SL ParBlazer 100 UV
Table 1: SL ParBlazer 100 UVVoltage (VAC) vs. Current*
"
Connecting SL
ParBlazer 100 UV to AC Power
"
on page 6
.
100
180
0.56
1.00
110
190
0.53
0.91
160
240
0.42
0.63
150
230
0.43
0.67
140
220
0.45
0.71
130
210
0.48
0.77
120
200
0.50
0.84
170
0.59
Voltage (AC)
Voltage (AC)
Total Current (A)
Total Current (A)
SL ParBlazer 100 UV luminaire.