HD6554/90 /91 /92 /94
6-10
Adjusting the scale factor for the strong/short (60ml) cup volume.
13. Remove the
water tank
from the machine. (for adjusting the right parameter, the internal
SW
will check if
the water level
sensor
is
activated
yes/no)
14. Press the 1- and 2 cup button simultaneously and plug the mains on.
15. Release the 1- and 2 cup button, if successful, the on/off LED will switch on less bright/intense as normal, indicating
the scale factor reprogramming has entered.
16. Depending if the volume has to de- or increase you have to push the one- or two-cup button.
Every time you push the 1- or 2-cup button, the LED will turn off for 0.5 second (feedback to user) and the scale factor
will be shortened or lengthened depending which button was pushed.
Pushing 1-cup button
, scale factor will be
shorten
approximately - 1 cc/ml (less coff ee)
Pushing 2-cup button
, scale factor will be
lengthen
approxi 1 cc/mL (more coff ee)
The new value will be stored when you switch the appliance off by pushing the main switch. (LED will turn off )
17. Turn appliance on again and brew one strong coff ee cup by pressing the 1-cup button twice, measure the volume. In
case the volume is not within specifi cation repeat steps 13 – 17.
18. End
Example table, switching from WEU to French/Spain specifi cation or vice versa, you need to execute below:
Change volume setting
Adjusting normal/smooth 1-cup volume
step 6- 12
Adjusting short/strong 1-cup volume
step 13 - 17
WEU => French/Spain
Push 7x 1-cups with water in tank
16x 2cups without tank
French/Spain => WEU
Push 7x 2-cups with water in tank
16x 1cups without tank
Restoring the Boiler_empty fl ag to production default:
Sometimes it is needed, that the boiler of the SENSEO have to be emptied.
This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e.g.
For those occasions, it is handy to restore the
Boiler_empty_fl ag
again to production default.
Bringing the SENSEO back into production status, has the benefi t the fl ush routine will be activated automatically when
installed by the consumer, see topic
Automatic fi lling procedure
.
How to
SET
the
Boiler_empty_fl ag
:
Keep the 1-cup button pressed while plugging in the power plug of the appliance in the mains socket
.
The main switch LED will blink very rapidly for approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, reconnect the power plug to the mains a second time and push the main
switch. The main switch LED should light continuously.
Repair instruction