background image

HD6554/90 /91 /92 /94

6-10

Adjusting the scale factor for the strong/short (60ml) cup volume.

13. Remove the 

water tank

 from the machine. (for adjusting the right parameter, the internal 

SW

 will check if 

the water level 

sensor

 is 

activated

 yes/no)

14.  Press the 1- and 2 cup button simultaneously and plug the mains on.

15.  Release the 1- and 2 cup button, if successful, the on/off  LED will switch on less bright/intense as normal, indicating 

the scale factor reprogramming has entered.

16.  Depending if the volume has to de- or increase you have to push the one- or two-cup button.

Every time you push the 1- or 2-cup button, the LED will turn off  for 0.5 second (feedback to user) and the scale factor 

will be shortened or lengthened depending which button was pushed.

Pushing 1-cup button

, scale factor will be 

shorten

 approximately   - 1 cc/ml (less coff ee)

Pushing 2-cup button

, scale factor will be 

lengthen

 approxi 1 cc/mL (more coff ee)

The new value will be stored when you switch the appliance off  by pushing the main switch. (LED will turn off )

17.  Turn appliance on again and brew one strong coff ee cup by pressing the 1-cup button twice, measure the volume. In 

case the volume is not within specifi cation repeat steps 13 – 17.

18. End

Example table, switching from WEU to French/Spain specifi cation or vice versa, you need to execute below:

Change volume setting

Adjusting normal/smooth 1-cup volume

step 6- 12

Adjusting short/strong 1-cup volume

step 13 - 17

WEU => French/Spain

Push 7x  1-cups with water in tank

16x  2cups without tank

French/Spain => WEU

Push 7x  2-cups with water in tank

16x  1cups without tank

Restoring the Boiler_empty fl ag to production default:

Sometimes it is needed, that the boiler of the SENSEO have to be emptied.

This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e.g.

For those occasions, it is handy to restore the 

Boiler_empty_fl ag

 again to production default.

Bringing the SENSEO back into production status, has the benefi t the fl ush routine will be activated automatically when 

installed by the consumer, see topic 

Automatic fi lling procedure

.

How to 

SET

 the 

Boiler_empty_fl ag

:

Keep the 1-cup button pressed while plugging in the power plug of the appliance in the mains socket

.

The main switch LED will blink very rapidly for approximately 1 second.

To check if the 

Boiler_empty_fl ag

 is really set, reconnect the power plug to the mains a second time and push the main 

switch. The main switch LED should light continuously.

Repair instruction

Summary of Contents for Senseo Original HD6554/90

Page 1: ...voir 750 cc Colour setting Deep red Functions º Coffee boost technology º Crema improvement º Strength select only for HD6554 HD6555 HD6556 Materials º Housing PP º Housing ABS only for HD6556 º Water container PP º Brew chamber PA º Spout POM º Hoses Silicon º Drip tray Driptray cover PP º Drip tray cover Stainless steel only for some HD6556 º Lever PC º Lever Chrome painted ABS only for some HD6...

Page 2: ...panish version 100 ml 69 C 73 C Water specification in mL without coffee pod 1 cup ml with 1 cup pod holder 2 cup ml with 1 cup pod holder General version normal cup 122 ml 133 10 266 10 French Spanish version normal cup 100 ml 109 20 218 20 All countries short cup 60 ml 71 10 142 10 Difference between left right volume 10ml 10ml Functional diagram Boiler Pump 3 way valve Brew head Water Container...

Page 3: ...tween back cover and brew chamber becomes visible Put the screwdriver in to the 4 rectangular holes snap locks at the back and gently pull the screwdriver such away that the lips of the snap locks are bent outwards If all clicks positions are loose it is possible to remove the back cover Reassemble follow steps backwards picture 1 picture 2 Removing Brew chamber head handle as follows Disassemble ...

Page 4: ...electing the right PCBA modus Enable Disable the Intensity select feature The PCBA is standard delivered with the Intensity select feature disabled this for easy servicing the existing SENSEO Original HD78xx HD6553 range with OPR Boiler installed The Intensity select function can be simple enabled disabled 1 Hold the 2 cups button while applying power to the appliance 2 Release the 2 cups button 3...

Page 5: ...nd push the one cup button 5 When the appliance has finished you are able to perform the volume adjustment Adjusting the normal 1 cup volume WEU or French Spain 6 Empty the cup podholder and push again for one cup setting measure the volume output with a graduated beaker In the table above you can find the requirements for the minimum maximum water volume output cc ml values 7 Unplug the appliance...

Page 6: ... the volume is not within specification repeat steps 13 17 18 End Example table switching from WEU to French Spain specification or vice versa you need to execute below Change volume setting Adjusting normal smooth 1 cup volume step 6 12 Adjusting short strong 1 cup volume step 13 17 WEU French Spain Push 7x 1 cups with water in tank 16x 2cups without tank French Spain WEU Push 7x 2 cups with wate...

Page 7: ...259 59541 3 way valve 18 4222 259 65481 Boiler assy OPR 230 V 19 4222 247 75271 TCO cap for OPR boiler 20 4222 247 43690 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 23 4222 259 68451 PCB assy OPR Intensity select 230 V 24 4222 259 68401 Button frame printed Black 26 4222 259 63422 On off button printed 27 4222 247 72932 Base plate Black 28 4222 247 05130 O r...

Page 8: ...HD6554 90 91 92 94 8 10 A 15 12 10 14 13 11 16 6 2 1 4 3 7 8 5 9 Exploded view ...

Page 9: ...HD6554 90 91 92 94 9 10 36 35 34 31 32 17 18 22 24 23 19 20 30 21 26 27 29 28 33 A Exploded view ...

Page 10: ...HD6554 90 91 92 94 10 10 Version history 17 07 Version 1 1 HD6554 90 HD6554 91 HD6554 92 HD6554 94 initial release ...