HD7860/63

Volume adjustment

The PCB circuit board makes it possible to adjust the volume 
output by means of pushing the one-cup and two-cup user 
controls.
How to adjust the volume output:
1.  Be sure the boiler is fi lled properly, other wise perform fi ll 

procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Be sure a 

pod holder

 is placed, but 

without

 a Coffee 

POD. (Only adjusting with 

plain

 water)

4.  Place a cup on the drip tray cover and push the one-cup 

button.

5.  When the appliance has fi nished it is stabilized to perform 

the volume adjustment. 

6.  Empty the cup, podholder and push again for one cup 

setting, measure the volume output with a graduated 
beaker.  In the table you can fi nd the requirements for 
the minimum / maximum volume output cc/mL values 
depending from the country version:

One-cup setting, Including Pod holder, 

water spec

.

(Without Coffee pod)

Min. water cc/mL

Max. water cc/mL

Argentina version

125

141

7.  Unplug the appliance from the mains.
8.  Press the 1- and 2 cup button simultaneously and plug the 

mains on.

9.  When above step succeeded the led will turn on 

continuously.

10. Depending if the volume has to de- or increase you have 

to push the one- or two cup button.
Every time you push the 1- or 2 cup button the LED will 
turn off for 0.5 second (feedback to user) and the pump 
time will be shortened or lengthened for 0.5 seconds 
depending which button was pushed.

Pushing 1 cup

 button pump, time will be 

shorten

 with 

0.5 sec is approximately − 3.5 cc/mL  (less coffee)

Pushing 2 cup

 button pump, time will be 

lengthen

 with 

0.5 sec is approxi 3.5 cc/mL  (more coffee)
When the volume has to increase with 10 cc for example, 
push the 

2 cup

 button 3 times.

The new value will be stored when you switch the 
appliance off by 

pushing

 the main switch.

(LED will turn off )

11. Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 6 - 11.

12. End.

Automatic fi lling procedure:

The Senseo PCB contains a automatic fi lling procedure 
software routine.
This fi ll routine is only meant for 

back-up

.

Normally the consumer has to follow the guidelines stated in 
the DFU.

The fi lling procedure functions as follows:
The consumer has to fi ll the water container and has to plug 
the appliance on the mains.
When the Senseo main switch has been pushed the main 
switch LED will light continuously.  This is only the case 
when the Senseo has not fi nished the fi lling procedure 
completely! (

First use

)

When the consumer pushes the one or two-cup button, the 
Senseo will start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping.
(Pump time approximately 22 seconds)
When the fi lling procedure has been successful the software 
will clear a 

Boiler_empty_fl ag

 in the Eeprom.

By means of this 

Boiler_empty_fl ag

 the system knows the 

boiler is fi lled or not!

When the Senseo is switched off or disconnected from the 
mains, the value of the 

Boiler_empty_fl ag

 is stored in the 

Eeprom chip.

Restoring the Boiler_empty_fl ag to production default:

Some times it is needed that the boiler of the Senseo have to 
be emptied.
This for instance in wintertime were the possibility exists that 
the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the 

Boiler_empty_

fl ag

 again to production default.

Bringing the Senseo back into production status, has the 
benefi t the fl ush routine will be activated automatically 
when installed by the consumer, see topic 

Automatic fi lling 

procedure

To 

SET

 the 

Boiler_empty_fl ag

 can be done by:

Keep the 1-cup button pressed while plugging in the power 
cord of the appliance

.

The main switch LED will blink very rapidly for 
approximately 1 second.
To check if the 

Boiler_empty_fl ag

 is really set, you should 

reconnect the power cord a second time to the net and push 
the main switch.
The main switch LED should light continuously. 

REPAIR INSTRUCTION

4-9

Summary of Contents for Senseo HD7860/63

Page 1: ...n on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 V Frequency 50 Hz Power consumption 1370 W Standby power 1 W Contents reservoir 1200 cc Colour setting Dark stroke OPTIONAL accessories No specific issues 12 03 CONTROL PCB L N Boiler Pump M Temp Sensor Wa...

Page 2: ... unlocking the two snap locks see picture 1 2 4 To remove the side panels unlock the 2 snap locks at each side and gently pull of the panels 5 Once the front and side panels are removed the inner components can be reached To be able to reach the inner parts of the lid assy follow below steps 1 Remove the two screws A which are holding the lid see picture A A 2 To remove the lid cover start with un...

Page 3: ...g agent Only citric acid based descalers are suitable for descaling the SENSEO machine This type of descaler descales the appliance without damaging it For the correct amount see under Descaling procedure below Each descaling mixture can be used only once After use the descaling mixture is no longer active We advise you to use the special SENSEO Descaler HD7006 Read the instructions on the package...

Page 4: ... measure the volume In case the volume is not within specification repeat steps 6 11 12 End Automatic filling procedure The Senseo PCB contains a automatic filling procedure software routine This fill routine is only meant for back up Normally the consumer has to follow the guidelines stated in the DFU The filling procedure functions as follows The consumer has to fill the water container and has ...

Page 5: ... 4222 259 37244 4222 259 50162 4222 247 61310 4222 247 61601 4222 259 51211 Padholder assy 1 cup Deep Black Padholder assy 2 cup Deep Black Driptray cover Driptray Deep Black Water container assy Transl Dark purple Argentina Lid Button assy Black Slider spring Ejector pin Brew chamber seal Distribution disk PCB hall sensor lid close Spout Deep Black Spout cover Deep Black Decorative spout cover Le...

Page 6: ...HD7860 63 EXPLODED VIEW 1 2 3 4 5 6 9 ...

Page 7: ...y 6 Never unscrew the screws D which are holding the button case assy When you do so the button case will not be air tight anymore which can result in steam water leakage This will cause that the button assy PCB will malfunction after some use 29 7 8 6 9 10 D D 7 9 ...

Page 8: ...HD7860 63 EXPLODED VIEW 17 18 19 16 11 15 12 13 14 31 8 9 ...

Page 9: ...HD7860 63 EXPLODED VIEW 20 26 25 23 24 21 22 27 28 32 9 9 ...

Reviews: