background image

HD7830/50

3-5

REPAIR INSTRUCTION & PARTS LIST

Automatic filling procedure:

The Senseo PCB contains an automatic fi lling procedure 
software routine.
This fi ll routine is only meant for 

back-up

.

Normally the consumer has to follow the guidelines stated in 
the DFU.
The fi lling procedure functions as follows:
The consumer has to fi ll the water container and has to plug 
the appliance on the mains.
When the Senseo main switch has been pushed the main 
switch LED will light continuously.  This is only the case 
when the Senseo has not fi nished the fi lling procedure 
completely! (

First use

)

When the consumer pushes the one or two-cup button, the 
Senseo will start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping.  (Pump 
time approximately 22 seconds)
When the fi lling procedure has been successful the software 
will clear a 

Boiler_empty_fl ag

 in the Eeprom.

By means of this 

Boiler_empty_fl ag

 the system knows the 

boiler is fi lled or not!

When the Senseo is switched off or disconnected from the 
mains, the value of the 

Boiler_empty_fl ag

 is stored in the 

Eeprom chip.

Restoring the Boiler_empty_flag to production default:

Some times it is needed that the boiler of the Senseo have to 
be emptied.
This for instance in wintertime where the possibility exists 
that the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the 

Boiler_empty_

fl ag

 again to production default in the Eeprom.

Bringing the Senseo back into production status, has the 
benefi t the fl ush routine will be activated automatically 
when installed by the consumer, see topic 

Automatic fi lling 

procedure

.

To 

SET

 the 

Boiler_empty_fl ag

 can be done by: 

Keep the 1-cup button pressed while plugging in the power 
cord of the appliance.

The main switch LED will blink very rapidly for 
approximately 1 second.

To check if the 

Boiler_empty_fl ag

 is really set, you should 

reconnect the power cord a second time to the net and push 
the main switch.
The main switch LED should light continuously.

Pos

Service code

Description

  1*
  2*
  3
  4
  5
  6
  7
  8
  9
10
11
12
13
14
15
16
17
18
19
20
21
22*
23
24
25
26
27
28
29
30

4222 259 36660
4222 259 36670
4222 247 42550
4222 247 45990
4222 259 37920
4222 240 05960
4222 247 41860
4222 247 45650
4222 247 41950
4222 247 06810
4222 240 05990
4222 247 41920
4222 259 37900
4222 259 34970
4222 259 35470
4222 247 06840
4222 247 06860
4222 247 35880
4222 259 36900
4222 247 05130
4222 259 35500
4222 259 36500
4222 247 50890
4222 247 50880
4222 247 05180
4222 247 35870
4222 247 39890
4222 247 05110
4222 259 34790
4213 247 05250

Padholder 1 cup 

Mid-Silver grey Soft grip

Padholder 2 cup 

Mid-Silver grey Soft grip

Collector Black
Spout cover 

Mid-Silver grey

Spout assy 

Silver grey

Driptray cover rim Top
Driptray Black
Lever 

Mid-Silver grey Soft grip

Pushrod
Sealing ring
Ejector pin
Distribution disk 

Black

Display assy Blue 

230 V

3-Way valve
Boiler assy 

V7.1 - 230 V

Hose
O-ring (pump elbo)
Pump Elbo
PCB assy incl. level sensor (2x)  230 V
O-ring (NTC)
NTC assy
Water tank 

Soft grey

Valve outlet 

Charcoal grey

Back cover 

Charcoal grey

WC sealing
Filter
WC socket hard
Corrugated tube
Pump 230 

V

Foot

* standardized parts!

Summary of Contents for Senseo HD7830/50

Page 1: ...uld function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption 1450 W Standby power consumption 1 2 W Contents reservoir 1200 cc Variable Coffee volume Min Normal and Max Coffee volume overview Min cc mL Normal cc mL Max cc mL France version 80 100 140 General version 80 122 145 Colou...

Page 2: ...ncrease with 10 cc for example push the 2 cup button 3 times The new value will be stored when you switch the appliance off by pushing the main switch LED will turn off 12 Turn appliance on again and brew one cup measure the volume In case the volume is not within specification repeat steps 6 11 13 End DISASSEMBLY AND RE ASSEMBLY ADVISE To remove the back cover follow below steps Remove Screw A se...

Page 3: ...oduction status has the benefit the flush routine will be activated automatically when installed by the consumer see topic Automatic filling procedure To SET the Boiler_empty_flag can be done by Keep the 1 cup button pressed while plugging in the power cord of the appliance The main switch LED will blink very rapidly for approximately 1 second To check if the Boiler_empty_flag is really set you sh...

Page 4: ...HD7830 50 4 5 EXPLODEDVIEW X B B 10 12 11 4 3 5 1 2 7 6 9 8 13 Warning Live Voltage applied alway disconnect plug from the mains when repairing ...

Page 5: ...HD7830 50 5 5 EXPLODEDVIEW X A 22 23 24 20 21 25 26 27 28 29 30 17 16 15 18 19 14 ...

Reviews: