HD7812/53
REPAIR INSTRUCTION
Restoring the Boiler_empty_fl ag to production default:
Some times it is needed that the boiler of the Senseo have to
be emptied.
This for instance in wintertime were the possibility exists that
the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the
Boiler_empty_
fl ag
again to production default.
Bringing the Senseo back into production status, has the
benefi t the fl ush routine will be activated automatically
when installed by the consumer, see topic
Automatic fi lling
procedure
.
To
SET
the
Boiler_empty_fl ag
can be done by:
Keep the 1-cup button pressed while plugging in the power
cord of the appliance
.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and push
the main switch.
The main switch LED should light continuously.
4-6
PARTS LIST
Pos
Service code
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
4222 259 35341
4222 259 38970
4222 259 39030
4222 247 39540
4222 247 37140
4222 247 66481
4222 247 35790
4222 247 35820
4222 240 06400
4222 247 07461
4222 259 06890
4222 259 50671
4222 259 52091
4222 247 06511
4222 259 52711
4222 247 05134
4222 259 39372
4222 259 06580
4222 247 40982
4222 259 36994
4222 259 37240
4213 247 05251
4222 259 35621
4222 247 41342
4222 247 39913
4222 247 41351
Brew chamber assy
Rich Silver
Padholder 1-cup
Black
Padholder 2-cup
Black
Foam chamber
Foam chamber cover
Drip tray cover
Black
Drip tray
Push rod
Slider spring
Brew chamber radial seal
Distrubutor assy
3-Way valve assy
Boiler assy
TCO V7.0 - 230 V
Pressure hose
Base PCB assy basic
1)
230
V
O-ring (NTC)
NTC assy
Water tank assy
Silver Grey
Valve outlet
Black
Back cover assy
Black
Pump
ULKA HF 230 V ~50 Hz
Foot
Front Cover
Rich Silver
Button Frame
Metallic Ebony
On/Off button
Button Cover
Metallic Ebony
1)
When you replace the PCB the coffee volume has to be re-set to your country specific setting.
Please carry out the Volume Adjustment Procedure to align the volume to your local specification
(see table).