background image

HD7810/70/B

3-5

Descaling

Regular descaling will prolong the life of your appliance and 
will guarantee optimal brewing results for a long time.
•  Follow the steps in the section headed “Preparing the 

appliance for use” see DFU (Direction for Use manual)

•  Instead of only water use a mix of water and Lemon sour.
•  For the best result leave the mix of water and Lemon sour 

for about 30 minutes in the appliance, before you start with 
flushing the appliance.

•  To get the best results repeat above-mentioned step once or 

twice.

•  When finished, flush the appliance twice by repeating the 

above-mentioned steps only use water instead.

Volume adjustment

The new PCB circuit board makes it possible to adjust the 
volume output by means of pushing the one-cup and two-cup 
user controls.
How to adjust the volume output:
1.  Be sure the boiler is fi lled properly, other wise perform fi ll 

procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Be sure a 

pod holder

 is placed, but 

without

 a Coffee 

POD.  (Only adjusting with 

plain

 water)

4.  Place a cup on the drip tray cover and push the one-cup 

button.

5.  When the appliance has fi nished it is stabilized to perform 

the volume adjustment. 

6.  Empty the cup and push again for one cup setting, 

measure the volume output with a graduated beaker.
In the table you can fi nd the requirements for the 
minimum / maximum volume output cc/mL values 
depending from the country version:

One-cup setting, Including Pod holder, 

water spec

.

(Without Coffee pod)

Min. water cc/mL

Max. water cc/mL

France version

104

120

General version

127

143

7.  Unplug the appliance from the mains.
8.  Press the 1- and 2 cup button simultaneously and plug the 

mains on.

9.  When above step succeeded the led will turn on 

continuously.

10. Depending if the volume has to de- or increase you have 

to push the 1- or 2 cup button.
Every time you push the 1- or 2 cup button the LED 
will turn off for 0.5 second (feedback to user) and the 
pump time will be shorten or lengthen for 0.5 seconds 
depending which button was pushed.

Pushing 1 cup

 button pump, time will be 

shorten

 with 

0.5 sec is approximately − 3.5 cc/mL (less coffee)

Pushing 2 cup

 button pump, time will be 

lengthen

 with 

0.5 sec is approxi 3.5 cc/mL (more coffee)

 

When the volume has to increase with 10 cc for example, 
push the 

2 cup

 button 3 times.

The new value will be stored when you switch the 
appliance off by pushing the main switch. (LED will turn 
off )

11. Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 6 - 11.

12. End.

Automatic filling procedure:

The Senseo PCB contains a new automatic fi lling procedure 
software.
This fi lling procedure functions as follows:
First the consumer has to fi ll the water container and has to 
plug the appliance on the mains.
When the Senseo main switch has been pushed and the 
consumer pushes the one or two cup button, the Senseo will 
start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping.
When the fi lling procedure has been successful the software 
will clear a 

Boiler_empty_fl ag

 in the EEPROM.

By means of this 

Boiler_empty_fl ag

 the system knows the 

boiler is fi lled or not!

When the Senseo is switched off or disconnected from the 
mains, the value of the 

Boiler_empty_fl ag

 is stored in the 

EEPROM chip.

The old way of fi lling the Boiler by pushing the 1 and 2 
cup button at the same time is still possible with this new 
software.

Restoring the Boiler_empty_flag to production default:

Some times it is needed that the boiler of the Senseo have to 
be emptied.
This for instance in wintertime were the possibility exists that 
the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the 

Boiler_empty_

fl ag

 again to production default in the EEPROM.

Bringing the Senseo back into production status, has the 
benefi t the fl ush routine will be activated automatically 
when installed by the consumer, see topic 

Automatic fi lling 

procedure

.

To 

SET

 the 

Boiler_empty_fl ag

 can be done by:

Keep the 1-cup button pressed while plugging in the power 
cord of the appliance

.

To check if the 

Boiler_empty_fl ag

 is really set, you should 

reconnect the power cord a second time to the net (do not 
push any buttons).
The LED should blink very fast for 0.5 seconds at the 
moment the power cord was connected to the net.

REPAIR INSTRUCTION

Summary of Contents for Senseo HD7810/70/B

Page 1: ...arding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 230 V Frequency 50 Hz Power consumption 1450 W Standby power consumption 0 002 kWh Contents reservoir 755 cc Colour setting Blue Deep purple SAP coding HD7810 70 B CONTROL PCB...

Page 2: ...cover handle as follows Place the screwdriver on the positions see picture 1 and lift the cover over the snap locks on both positions The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod see picture 2 to each other so that the two pins will get out of the hinge position on the brew cham...

Page 3: ... with 0 5 sec is approximately 3 5 cc mL less coffee Pushing 2 cup button pump time will be lengthen with 0 5 sec is approximately 3 5 cc mL more coffee When the volume has to increase with 10 cc for example push the 2 cup button 3 times The new value will be stored when you switch the appliance off by pushing the main switch LED will turn off 11 Turn appliance on again and brew one cup measure th...

Page 4: ...760 4222 247 39540 4222 240 06670 4222 247 35790 4222 259 04380 4222 247 38330 4222 247 35820 4222 247 06810 4222 259 06890 Brewchamber assy complete Blue Pad holder single Deep purple Pad holder double Deep purple Foam chamber cover Deep purple Foam chamber Drip tray cover Drip tray Brewchamber Lid Blue Lever Deep purple Push Rod Brew chamber radial seal Distrubutor assy changed ...

Page 5: ...0 4222 259 04390 4222 259 20100 Valve 3way Boiler assy compl 230V 1400W Temp sensor Hose Pump Elbo O ring elbo Water tank assy Aqua Blue XL 10 Cups Water tank assy Silent blue Pos Service code Description 20 21 22 23 24 25 26 4222 247 36640 4222 247 39970 4222 247 35870 4222 247 05100 4222 247 39890 4222 247 05110 4213 247 05250 Valve outlet Blue Back cover Blue Filter WC Sealing WC socket Hard Co...

Reviews: