REPAIR INSTRUCTION

Descaling

Descaling is an important element in Senseo maintenance.
It should be done at least once every 3 months, up to 6 times 
a Year!
This will prolong the life of your appliance and will guarantee 
optimal brewing results for a long time.

Use the correct descaling agent.

Only citric acid-based descalers are suitable for descaling 
the SENSEO

®

 machine.  This type of descaler descales the 

appliance without damaging it.  For the correct amount, see 
under ‘Descaling procedure’ below.  Each descaling mixture 
can be used only once.  After use, the descaling mixture is no 
longer active.
We advise you to use the special SENSEO

®

 Descaler 

(HD7006).  Read the instructions on the package of the 
descaling agent.
Never use a descaling agent based on mineral acids such as 
sulphuric acid, hydrochloric acid, sulphamic acid and acetic 
acid (e.g. vinegar).  These descaling agents may damage your 
SENSEO

®

 coffee machine.

•  Follow the steps in the section headed “Descale the 

appliance” see DFU (Direction for Use manual)

Volume adjustment

The PCB circuit board makes it possible to adjust the volume 
output by means of pushing the one-cup and two-cup user 
controls.
How to adjust the volume output:
1.  Be sure the boiler is fi lled properly, other wise perform fi ll 

procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Be sure a 

pod holder

 is placed, but 

without

 a Coffee 

POD.  (Only adjusting with 

plain

 water)

4.  Place a cup on the drip tray cover and push the one-cup 

button.

5.  When the appliance has fi nished it is stabilized to perform 

the volume adjustment. 

6.  Empty the cup, podholder and push again for one cup 

setting, measure the volume output with a graduated 
beaker.  In the table you can fi nd the requirements for 
the minimum / maximum volume output cc/mL values 
depending from the country version:

One-cup setting, Including Pod holder, 

water spec

.

(Without Coffee pod)

Min. water

cc/mL

Max. water

cc/mL

France version

104

120

General (Europe) version

125

141

Spain version

65

81

Brazil version

65

81

7.  Unplug the appliance from the mains.
8.  Press the 1- and 2 cup button simultaneously and plug 

the mains on.

9.  When above step succeeded the led will turn on 

continuously.

10. Depending if the volume has to de- or increase you have 

to push the one- or two cup button.
Every time you push the 1- or 2 cup button the LED will 
turn off for 0.5 second (feedback to user) and the pump 
time will be shortened or lengthened for 0.5 seconds 
depending which button was pushed.

Pushing 1 cup

 button pump, time will be 

shorten

 with 

0.5 sec is approximately − 3.5 cc/mL  (less coffee)

Pushing 2 cup

 button pump, time will be 

lengthen

 with 

0.5 sec is approxi 3.5 cc/mL  (more coffee)
When the volume has to increase with 10 cc for example, 
push the 

2 cup

 button 3 times.

The new value will be stored when you switch the 
appliance off by pushing the main switch.
(LED will turn off )

11. Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 6 - 11.

12. End.

Automatic fi lling procedure:

The Senseo PCB contains a automatic fi lling procedure 
software routine.
This fi ll routine is only meant for 

back-up

.

Normally the consumer has to follow the guidelines stated in 
the DFU.

The fi lling procedure functions as follows:
The consumer has to fi ll the water container and has to plug 
the appliance on the mains.
When the Senseo main switch has been pushed the main 
switch LED will light continuously.  This is only the case 
when the Senseo has not fi nished the fi lling procedure 
completely! (

First use

)

When the consumer pushes the one or two-cup button, the 
Senseo will start automatically the pump to fi ll the boiler.
When the boiler is fi lled the pump stops pumping.
(Pump time approximately 22 seconds)
When the fi lling procedure has been successful the software 
will clear a 

Boiler_empty_fl ag

 in the Eeprom.

By means of this 

Boiler_empty_fl ag

 the system knows the 

boiler is fi lled or not!

When the Senseo is switched off or disconnected from the 
mains, the value of the 

Boiler_empty_fl ag

 is stored in the 

Eeprom chip.

3-7

Summary of Contents for Senseo HD7810/00

Page 1: ...ments regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 230 V Frequency 50 Hz Power consumption 1450 W Standby power consumption 1W Contents reservoir 750 cc Colour setting Zinc Brown Cashmere grey CONTROL PCB L N Boiler Pump ...

Page 2: ...er on the positions see picture 1 and lift the cover over the snap locks on both positions The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod see picture 2 to each other so that the two pins will get out of the hinge position on the brew chamber To remove lever from lid cover take a s...

Page 3: ... mL France version 104 120 General Europe version 125 141 Spain version 65 81 Brazil version 65 81 7 Unplug the appliance from the mains 8 Press the 1 and 2 cup button simultaneously and plug the mains on 9 When above step succeeded the led will turn on continuously 10 Depending if the volume has to de or increase you have to push the one or two cup button Every time you push the 1 or 2 cup button...

Page 4: ...ult Bringing the Senseo back into production status has the benefit the flush routine will be activated automatically when installed by the consumer see topic Automatic filling procedure To SET the Boiler_empty_flag can be done by Keep the 1 cup button pressed while plugging in the power cord of the appliance The main switch LED will blink very rapidly for approximately 1 second To check if the Bo...

Page 5: ... 4222 259 52091 4222 247 61940 4222 247 43690 Distributor assy 3 way valve Boiler assy TCO cap Boiler pin cap V7 0 230 V 21 22 23 24 25 4222 247 61971 4222 247 06511 4222 259 61701 4222 247 73201 4222 247 73221 Suspension bracket Pressure hose PCB assy 1 Button frame On off button cover Cashmere grey Cashmere grey 26 27 28 29 30 4222 247 39913 4222 247 73211 4222 247 05130 4222 259 39372 4222 247 ...

Page 6: ...HD7810 00 01 03 EXPLODEDVIEW A 15 12 10 14 13 11 16 6 2 1 4 3 7 8 5 9 6 7 ...

Page 7: ...HD7810 00 01 03 EXPLODEDVIEW 36 35 34 31 32 17 18 22 24 25 23 19 20 30 21 26 27 29 28 33 A 7 7 ...