MOUNTING YOUR LUMINAIRE 

 
Your luminaire uses a theatre lamp with a grid filament. To avoid premature 
lamp failure it is essential that the luminaire is always mounted so the yoke is 
horizontal and with the lamp base down, i.e. the lamp adjustment knob is at 
the bottom of the rear lamp plate. 
 

 
 
 
To mount on the theatre standard scaffold pipe (48mm O.D.) use a theatre 
hook clamp (G clamp) (Order Code: 20HC). Your luminaire is supplied with a 
12mm set screw, washers and a nut.  Thread the set screw through the yoke 
from the inside, put on a washer, then the hook clamp, another washer and 
then do up finger tight with the nut.  
To mount on a telescopic stand, reverse the yoke under the luminaire and bolt 
the stand’s spigot

 

onto the 10mm set screw. 

 

 
SAFETY CHAIN 
 
A safety chain MUST always be used when rigging luminaires on bars, ladders etc.  The Acclaim 
Fresnel and PC have an integral safety chain that can be retracted into the luminaire when not in use. 
To use the safety chain, unscrew the safety chain locking clamp located on the top of the lamphouse, 
pull the clip out from the rear of the lamphouse, and loop the safety chain around the bar fastening the 
clip onto the safety chain. Be careful to allow sufficient slack to enable the luminaire to be focused 
freely. To replace the safety chain, remove the rear lamphouse moulding, slide out the safety chain 
locking clamp, and pull out the safety chain, taking care to retain the safety chain loop bar. Reverse the 
process with a new safety chain. Replace only with the approved safety chains available from Selecon 
or your distributor. 
 
FOCUSING 

 

The variable beam of the Acclaim Fresnel or PC is altered by adjusting the position of the lamp / reflector 
assembly relative to the lens. Finger tight pressure only is necessary to lock the lamp / reflector assembly off in 
the chosen positions. A beam angle reference scale is provided to pre-focus the luminaire if desired. 
 
When focusing, first spot the beam down, position the luminaire and then flood the beam to cover the area 
required. The beam can then be shaped using the four-flap barndoor accessory (Order Code: 20BDMF). 
 

 

YOKE PIVOT ADJUSTMENT 

 
The yoke on the Acclaim range can be positioned anywhere in the channel that runs the length of the luminaire. 
This is useful to achieve the best balance if using a colour changer or other accessory mounted on the front of 
the luminaire, or to fit the luminaire in space restricted positions. 
 
The yoke balance point is factory set on the lamp house for normal applications.  To move the yoke, loosen the 
M8 bolt at the bottom pivot point of the yoke on the right side of the luminaire.  Release the tilt locking clamp on 
the left side of the luminaire, and slide the yoke to the required position. Check the yoke is evenly positioned on 
each side and tighten the M8 bolt, and the tilt locking clamp. To return the yoke to its original balance point, 
align the yoke to the balance point marked on the focus reference scale. 
 

PAN AND TILT ADJUSTMENT   

 
To pan your luminaire loosen the yoke nut and bolt holding the hook clamp onto the yoke and adjust the yoke 
as required, then  retighten the yoke nut and bolt. 
 
The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. The tilt 
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob 
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle 
reference scale is provided on the locking clamp disc to pre-focus the luminaire if desired. 

 

© June 2009 All Rights Reserved 

 

Summary of Contents for Selecon ACCLAIM FRESNEL

Page 1: ...urther assistance contact your Selecon dealer or Selecon LAMPING YOUR LUMINAIRE Before lamping DISCONNECT THE LUMINAIRE FROM THE POWER SUPPLY Be aware also that the lamp or luminaire may still be hot so exercise the necessary caution to avoid burns Please note also that these luminaires are not suitable for mounting on a normally flammable surface The Selecon Acclaim Fresnel and PC range is design...

Page 2: ...y relative to the lens Finger tight pressure only is necessary to lock the lamp reflector assembly off in the chosen positions A beam angle reference scale is provided to pre focus the luminaire if desired When focusing first spot the beam down position the luminaire and then flood the beam to cover the area required The beam can then be shaped using the four flap barndoor accessory Order Code 20B...

Page 3: ... can be safely carried out by non approved personnel Refer below Safety Maintenance note SAFETY MAINTENANCE Selecon has manufactured this luminaire in accordance with recognised best practices to recommended international safety standards It is your responsibility to maintain this luminaire in good and safe working condition Repairs should only be carried out by suitably qualified persons Do not o...

Page 4: ...ty bond supplied with 1 x color frame 1 x M12 nut bolt set and instruction leaflet LAMPS 120V 575W Ushio JCS120V 575WC 300hrs average life 575W Ushio JCS120V 575WX 1500hrs average life 650W FRK 16 900 lumens 200hrs average life 650W FRE 15 000 lumens 400hrs average life Tests conducted using a standard FRK 650W 120V lamp PHYSICAL DATA PC Metric Weight 3 5kg Packed 3 9kg Carton Size 460 x 225 x 175...

Page 5: ...mens 200hrs average life 650W FRE 15 000 lumens 400hrs average life Tests conducted using a standard FRK 650W 120V lamp LIMITED WARRANTY Selecon New Zealand Ltd Selecon warrants its luminaires against defects in materials or workmanship The term of this warranty is based on the product usage and is from the date of delivery Usage Entertainment Theatre Term Three Years Entertainment Theatre relates...

Page 6: ...operating and safety procedures specified by Selecon or imposed by law This is an express warranty Selecon disclaims any other express or implied warranties including warranties of merchantability or fitness for purpose to the maximum extent permitted by law Some jurisdictions do not allow limitations or disclaimers of implied or statutory warranties Some jurisdictions do not allow disclaimers or ...

Reviews: