8.  Pump - Cleaning restrictor

Service center to perform pump restrictor cleaning via following step if observe pump not pumping water:
1.  De-assemble water tube of pump.

2.  Clean restrictor via sharp object.

3.  Re-assemble stand

9.  Cartridge compartment - Cleaning

Service center to perform cleaning of Cartridge compartment via following step:
1.  Open Cartridge lid of stand.
2.  Clean out any residue located on the mesh.

REPAIR INSTRUCTIONS

Summary of Contents for PerfectCare Pure GC7640

Page 1: ...roperly and has to meet the safety requirements and legal regulations as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240V Frequency 50 60 Hz Power 2800W Dimension F box 400 L x 230 W x 280 H mm Weight of iron 1 20 kg Demineralized water only PerfectCare Pure is designed to be used only with demineralized or distilled water Demineralized or distilled water prevent your app...

Page 2: ...rews C1 C2 Remove CHASSIS 8 Remove Screws D1 D2 D3 Remove HOUSING LIGHT RING ASSY 4 Remove DOSING HEAD 2 Remove LED ASSY 5 Remove Screw E1 Remove HOSE CORD MTD ASSY 7 Remove Screws F1 F2 G1 Remove COVER 3 Remove Screws H1 H2 Remove SOLEPLATE ASSY 1 DISASSEMBLYADVICE IRON PARTS LIST IRON Pos Service code Description 1 2 3 4 5 4239 021 77141 4239 026 53722 4239 026 60991 4239 021 86751 4239 021 7881...

Page 3: ...GC7640 3 8 G1 A1 D1 H2 E1 C1 C2 H1 F2 F1 D2 D3 B1 10 Trigger spring cap Dosing seal Reflector 11 9 4 8 7 2 6 5 3 1 EXPLODEDVIEW IRON ...

Page 4: ...SSY 23 Remove FILLING DOOR 24 Remove Screws E1 E2 Remove POWER BOARD PCBA 27 Remove PUMPASSY 16 Remove Screw F1 Remove POWER BUTTON 26 Remove Screws G1 G2 Remove POWER CORD 25 DISASSEMBLYADVICE STAND PARTS LIST STAND Pos Service code Description 12 13 14 15 16 4239 026 61041 4239 026 61051 4239 026 61061 4239 021 81341 Stand bottom Stand bottom cap Belt loop left Belt loop right Pump assy 17 18 19...

Page 5: ... B4 20 22 20 23 15 14 16 19 30 31 21 22 28 32 24 12 26 27 29 29 13 Cartridge clip Clamping plate LID clip Cord clamp Hose hose cord mounted assy Tube cartridge inlet Tube cartridge outlet Button frame Cartridge LID rubber Rear lock rubber 18 17 25 EXPLODEDVIEW STAND 35 ...

Page 6: ... Probe Welded Assy Marlin Sensing Probe Welded Assy WA4 Marlin SG Fuse to SG L WA6 Marlin SG Fuse to Hosecord L WA7 Marlin SG N to Hosecord N Marlin SG Thermistor Assy Thermal Fuse Iron Earth Point Hosecord to Stand Iron Heater Hosecord to Iron Iron L Flex L Flex N Iron N Earth interconnection Iron PCBA HE POWER PCBA COND SENSE FLEX PUMP WIRING DIAGRAM ...

Page 7: ...n IEC requirement Soleplate temperature Deg C Materials for example Test point Minimum Maximum 120 143 All fabric types 2 Leakage current Check that leakage current is within IEC requirement Measure leakage current between LIVE NEUTRAL EARTH IEC requirement is that at 230V supply the EARTH leakage current must be less than 0 75 mA 3 Water leakage Functionality Check that there is no water leakage ...

Page 8: ...e pump not pumping water 1 De assemble water tube of pump 2 Clean restrictor via sharp object 3 Re assemble stand 9 Cartridge compartment Cleaning Service center to perform cleaning of Cartridge compartment via following step 1 Open Cartridge lid of stand 2 Clean out any residue located on the mesh REPAIR INSTRUCTIONS ...

Reviews: