Smart Energy Plug PAN44

    

This plug-in ON/OFF switch PAN44 is a devices displaying the Z-Wave Plus

TM

 logo can

also be used security enabled wireless switch, based on Z-Wave Plus technology. Z-
Wave Plus

TM

  enabled with it regardless of the manufacturer, and can also be used in

other manufacturer’s Z-Wave

TM

  enabled networks. Remote On/Off control of the con-

nected load is possible with another manufacturer’s wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN44 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.

This plug-in ON/OFF switch is able to detect instance wattage (1560W/UL/TW/JP) and
overload current (14.5A with resistive load) of connected lights or appliances. When de-
tecting overload state, the Switch will be disabled and it’s On/Off button will be lockout
of which LED will flash quickly. However, unplug and reconnect the switch will reset its
overload condition to normal status.

Specification

Operating Voltage

100V-240V~ 50Hz~60Hz

Maximum Load (Ampere)

13A (Resistive load) PAN44-1; PAN44-2

Range

Minimum 40 m in door 100m outdoor line of sight

Operating Temperature

0°C ~ 40°C

Frequency Range

908.4MHz & 916.0MHz/ USA (PAN44-1); 
920~927MHz/ Taiwan/ Japan (PAN44-2)

RF Maximum Power

+10dBm (Peak), -10dBm (Average)

 

** Specifications are subject to change and improvement without notice. 

Troubleshooting

 

Symptom

Cause of Failure

Recommendation

The   Switch   not   working

and LED off

1.The Switch is not plugged into

the electrical outlet properly

2.The Switch break down

1. Check power connections

2. Don’t open up the Switch

and send it for repair.

The   Switch   LED   illumi-

nating, but cannot control

the Switch of the load at-

tached

1.Check   if   the   load   plugged   into

the   Switch   has   its   own   ON/OFF

switch

2. The switch is protected

1. Set the ON/OFF switch of

the load attached to ON

2. Unprotected the switch or

follow the instruction of pro-

tection.

The   Switch   LED   illumi-

nating,   but  the  Detector

cannot control the Switch

1. Not carry out association

2. Same frequency interference

1. Carry out association

2. Wait for a while to retry

LED   keep   flashing,   but

cannot control

Overload occurs

Remove the load attached or

check max. load cannot ex-

ceed 13A (Resistive load)

 

Summary of Contents for PAN44

Page 1: ... unplug and reconnect the switch will reset its overload condition to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN44 1 PAN44 2 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 908 4MHz 916 0MHz USA PAN44 1 920 927MHz Taiwan Japan PAN44 2 RF Maximum Power 10dBm Peak 10dBm Average Spec...

Page 2: ...to toggle switch on and off or carries out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that it has not been assigned a node ID The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access...

Page 3: ...or 5 seconds 3 IDs are excluded LED 2s On 2s Off Enter auto inclusion Association 1 The PAN44 is an always listening Z Wave device so associations may be added or removed by a controller at any time Or If your controller re quires to have the PAN44 send a node information frame or NIF for associations then pressing the On Off button three times within 2 sec onds will cause the PAN44 to send its NI...

Page 4: ...y press and release the On Off but ton The LED will turn OFF and the load plugged into the Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller the Switch will report its On Off sta...

Page 5: ...5A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumu lated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive th...

Page 6: ...eter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 M...

Page 7: ...nstant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN44 will disable Watt auto report function The default value is 720 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 PAN44 will report its Ac cumulated Power Consumption KWh to Group1 node every 1 hour The maximum interval to report its Accumulated Power Consumption KWh is 227 55 days 10mi...

Page 8: ...e default setting is 1 Enable Whenever PAN44 manually switch on or off it will send BINARY_SWITCH_ REPORT to the node of group1 1 Firmware update over the air OTA PAN44 is based on 700 series SoC and supports Firmware Update Command Class it can receive the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 2 The ...

Page 9: ...t generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipme...