2-3-4
E9015MA
6. Press "
L
CH
??
" button on the remote control unit until
the CTL waveform has shifted from its original posi-
tion (not the position achieved in step 5, but the
position of CTL waveform in step 4) by approxi-
mately -2msec. Make sure that the envelope is
simply attenuated (shrinks in height) once CTL
waveform passes its original position and is further
brought in the minus direction.
7. Set the Tracking Control Circuit to the center posi-
tion by pressing "VCR" button and "
K
CH" button on
the remote control unit then pressing "PLAY" button
on the unit.
1-C. Checking/Adjustment of Envelope
Waveform
Purpose:
To achieve a satisfactory picture and precise tracking.
Symptom of Misalignment:
If the envelope output is poor, noise will appear in the
picture. The tracking will then lose precision and the
playback picture will be distorted by any slight varia-
tion of the Tracking Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) on the
Main CBA. Use TP504 (RF-SW) as a trigger.
2. Playback the Gray Scale on the Alignment Tape
(FL6NS8). Set the Tracking Control Circuit to the
center position by pressing "VCR" button and
"
K
CH" button on the remote control unit then
pressing "PLAY" button on the unit. Adjust the
height of Guide Rollers [2] and [3] (Fig. M3, Page
2-3-3) watching the oscilloscope display so that the
envelope becomes as flat as possible. To do this
adjustment, turn the top of the Guide Roller with
the Guide Roller Adj. Screwdriver.
3. If the envelope is as shown in Fig. M7, adjust the
height of Guide Roller [2] (Refer to Fig. M3) so that
the waveform looks like the one shown in Fig. M9.
4. If the envelope is as shown in Fig. M8, adjust the
height of Guide Roller [3] (Refer to Fig. M3) so that
the waveform looks like the one shown in Fig. M9.
5. When Guide Rollers [2] and [3] (Refer to Fig.M3)
are aligned properly, there is no envelope drop
either at the beginning or end of track as shown in
Fig. M9.
Note: Upon completion of the adjustment of Guide
Rollers [2] and [3] (Refer to Fig. M3), check the X
Value by pushing the "
K
CH" or "
L
CH
??
" buttons alter-
nately, to check the symmetry of the envelope. Check
the number of pushes to ensure center position. The
number of pushes "
K
CH" button to achieve 1/2 level of
envelope should match the number of pushes "
L
CH
??
"
button from center. If required, redo the “X Value
Alignment.”
1-D. Azimuth Alignment of Audio/Control/
Erase Head
Purpose:
To correct the Azimuth alignment so that the Audio/
Control/Erase Head meets tape tracks properly.
Symptom of Misalignment:
If the position of the Audio/Control/Erase Head is not
properly aligned, the Audio S/N Ratio or Frequency
Response will be poor.
1. Connect the oscilloscope to the audio output jack
on the rear side of the deck.
2. Playback the alignment tape (FL6NS8) and confirm
that the audio signal output level is 6kHz.
3. Adjust Azimuth Adj. Screw so that the output level
on the AC Voltmeter or the waveform on the oscil-
loscope is at maximum. (Fig. M6)
Dropping envelope level at the beginning of track.
Fig. M7
Dropping envelope level at the end of track.
Fig. M8
Envelope is adjusted properly. (No envelope drop)
Fig. M9
Summary of Contents for MX5100VR/00
Page 10: ...1 5 1 E9015IB OPERATING CONTROLS AND FUNCTIONS MX5100VR 00 ...
Page 11: ...1 5 2 E9015IB ...
Page 12: ...1 5 3 E9015IB ...
Page 13: ...1 5 4 E9016IB MX5100VR 05 ...
Page 14: ...1 5 5 E9016IB ...
Page 15: ...1 5 6 E9016IB ...
Page 16: ...1 5 7 E9017IB MX5100VR 02 ...
Page 17: ...1 5 8 E9017IB ...
Page 18: ...1 5 9 E9017IB ...
Page 62: ...BE9015F01011A Main CBA Bottom View 1 12 35 1 12 36 ...
Page 70: ...DAC CBA Top View 1 12 51 1 12 52 BE9015F02011 DAC CBA Bottom View ...
Page 92: ...AF BOARD Top View AV_OSAKA 3139 113 3517 pt 5 dd wk 335 31391133517pt5 1 12 95 1 12 96 ...
Page 93: ...AF BOARD Bottom View 31391133517pt5 AV_OSAKA 3139 113 3517 pt 5 dd wk 335 1 12 97 1 12 98 ...
Page 151: ...3 1 REVISION LIST Version 1 0 Initial release ...