transformateur]
REMARQUE:
Ce schema est conforme au Code
national de l'electricite.
[Support de
[Cable sous-marin]
[Conduit (non compris)]
1 pi
4 pi
[Transformateur (non compris)]
Transformer Support
Conduit (By others)
Underwater Cable
Transformer (Not included)
Not less than 16"
4 ft.
1 ft.
Code Article 680-5, 680-21, and 680-52.
This diagram is per National Electrical
NOTE:
DECK
50W, MR16, WFL, 38°
50W, MR16, MFL, 24°
50W, MR16, NSP, 12°
42W, MR16, WFL, 36°
42W, MR16, MFL, 20°
42W, MR16, NSP, 9°
35W, MR16, WFL, 35°
35W, MR16, MFL, 21°
35W, MR16, NSP, 12°
20W, MR16, WFL, 40°
20W, MR16, NSP, 13°
20W, MR16, VNSP, 6°
des lampes suivantes.]
[Ce luminaire peut etre pourvu
used in this fixture.
The following lamps may be
CAUTION!
1. TO PREVENT ELECTRICAL SHOCK, DISCONNECT TRANSFORMER FROM ELECTRIC SUPPLY BEFORE SERVICING.
2. DO NOT let the fixture freeze. This may cause cracking or deformation that may cause
the fixture to leak, or cause safety problems.
3. DO NOT hold fixture by or pull the underwater cable. If wire is pulled it may break
the liquid-tight seal and void the warranty.
4. DO NOT use the fixture out of water with the polycarbonate lens guard on. If the fixture is not
used as an under-water fixture, remove the clear polycarbonate lens guard or it will distort and soften.
and result in possible leakage.
5. DO NOT loosen or remove the liquid-tight connector, this will damage the factory set seal
8. The fixture is rated Max. 50 W, (12) Volt AC, DO NOT connect fixture to any other voltage.
6. The end of the underwater cable MUST BE POTTED to prevent moisture from entering the cable
and consequently into the fixture. (See fig. 1).
7. The fixture is to be directly connected to a U.L. LISTED Low Voltage Transformer intended for this
application. (See fig. 2).
SERVICING INSTRUCTIONS
1. LAMP INSTALLATION / REPLACEMENT:
a) Remove the fixture from the water.
b) Loosen cover locking screw to remove cover.
c) Unscrew the cover by turning it counterclockwise. Remove the lens
and O-ring.
d) Remove and install lamp. DO NOT exceed the maximum 50 W
rating. The lamp is a standard 12V halogen, type MR-16, bi-pin.
e) To remove lamp, pull on lamp reflector. Do not pull on the small
bulb within the reflector.
f ) To install lamp, plug the lamp into the bi-pin socket. DO NOT touch
the new halogen bulb. Only touch the lamp reflector. Touching
the bulb may shorten lamp life.
g) The O-ring seating surfaces must be clean. Be certain that the
O-ring is in good condition and clean. Reinstall O-ring and lens.
h) Reinstall the fixture cover. Look through the (3) slots on cover, hand
tighten cover by turning it clockwise until the (3) tabs on cover
touch the stops on the housing.
i ) Tighten the cover locking screw to lock in place.
2. MAKE CERTAIN NO WATER OR MOISTURE IS INSIDE FIXTURE PRIOR TO
REASSEMBLING.
3. CLEANING: The lens will require periodic cleaning. Wipe off the
outside of the lens with a soft cloth. DO NOT use abrasives. This may
damage the lens.
page 2 of 2