2 - 2
SERVICE MEASUREMENT
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
LF Voltmeter
e.g. PM2534
DUT
RF Generator
e.g. PM5326
S/N and distortion meter
e.g. Sound Technology ST1700B
Tuner SW
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday«s cage.
Use a bandpass filter (or at least a high pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).
Ri=50
Ω
Aerial replacement
Capacitor
R=50
Ω
Bandpass
250Hz-15kHz
e.g. 7122 707 48001
LF Voltmeter
e.g. PM2534
DUT
S/N and distortion meter
e.g. Sound Technology ST1700B
Frame aerial
e.g. 7122 707 89001
Tuner AM (MW,LW)
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday«s cage.
RF Generator
e.g. PM5326
Ri=50
Ω
Low pass filter 22kHz
L
R
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
S/N and distortion meter
e.g. Sound Technology ST1700B
DUT
CD
Use Audio Signal Disc SBC429 4822 397 30184 (replaces test disc 3)
L.P.F. = 13
th
order filter 4822 395 30204
Summary of Contents for MCD703/37
Page 2: ...1 1 HANDLING CHIP COMPONENTS ...
Page 11: ...5 1 5 1 SOFTWARE VERSION AND UPGRADING ...
Page 12: ...5 2 5 2 SET BLOCK DIAGRAM ...
Page 13: ...5 3 5 3 SET WIRING DIAGRAM ...
Page 15: ...6 2 6 2 LAYOUT DIAGRAM VFD KEY BOARD ASSEMBLY ...
Page 17: ...7 2 7 2 LAYOUT DIAGRAM TUNER BOARD ...
Page 19: ...8 2 8 2 LAYOUT DIAGRAM DVD BLOCK ...