For air discharge:
Level
General (kV)
USA (kV)
Requirement
1
0-4
0-6
No deviations allowed.
2
>4-8
>6-8
Short perceptible deviations allowed.
3
-
>15-18
No loss of stored data allowed.
General requirement:
1. 10 arcs for positive and negative polarity for unit “on” and “off” for 1kV incremental steps.
2. Component or mechanical damage is not allowed. No loss of fixed stored data (stored in EEPROMs).
3. Hang-ups and malfunctions are allowed, as long as the customer can “recover” from the hang-up by
pressing the Standby or ON/OFF button of the set.
4. Failures that disappear only by unplugging the AC mains cord and/or power sources are not acceptable.
2.6
Environmental Condition
The environmental condition requirements and test method is according to UAN-D1590.
Ambient temperature
: max. 40 ° C - all climates
Apparatus acc. to spec.
: +5 to + 35 ° C
Vibration test (acc. IEC 60 068/2/6) : operational vibration test to be proceeded in operating position of the
set.
2.7
Quality
PQR-class: class 2 according to BLC A&MA PQR handbook V2.1 (2006-10-02)
Lifetime: 7 years
Tested According to: General Test Instruction UAN-D 1591
Measured According to: UAN_L 1059 unless otherwise stated
Technical Specification and Connection Facilities
1-5
Summary of Contents for MCD1065/51/98
Page 24: ...8 2 Fig D3 Fig D5 Fig D4 Cabinet Disassembly Instructions Fig D6 A02 A03 A04 A02 ...
Page 28: ...Wiring Diagram Display Board Decoder Board AMP Board DVD Loader Power Board 11 1 11 1 ...
Page 31: ...AMP Board Layout Diagram 12 3 12 3 ...
Page 33: ...Display Board Layout Diagram 12 5 12 5 ...
Page 35: ...Power Board Layout Diagram 12 7 12 7 ...
Page 42: ...Decoder Board Layout Diagram 12 14 12 14 ...
Page 44: ...Revision List Revision List Version 1 0 Initial Release 14 1 ...