3.6 PAL/SECAM CONVERTER CIRCUIT
Note:
• Unless otherwise specified in this P/S Converter cir-
cuit adjustments, all measuring points and adjustment
parts are located on the P/S Converter board.
Fig. 3-6-2 PAL burst position
Colour burst signal
H-SYNC
H.rate
C
(Converted colour)
Y
Specified value (G)
3.6.2 SECAM burst position
(1) Observe the waveforms appeared at the measuring
points (D1) and (D2).
(2) Adjust the adjustment part (F) so that the waveforms tim-
ing width between the H-SYNC and the colour burst sig-
nal becomes the specified value (G).
Signal
(A1)
• Color (colour) bar signal [SECAM]
Mode
(B)
• EE
Equipment
(C)
• Oscilloscope
Measuring point (D1)
• CN1601 Pin 7
(D2)
• CN1601 Pin 3
Adjustment part
(F)
• VR1603
Specified value
(G)
• T = 5.6 ± 0.1 µsec
3.6.1
Colour difference level
(1) Observe the C (converted colour) waveform at the meas-
uring point (D).
(2) Adjust the adjustment part (F1) so that the higher level
of the Yellow and Blue of the C waveform becomes the
specified value (G1).
(3) Adjust the adjustment part (F2) so that the higher level
of the Green and Magenta of the C waveform becomes
the specified value (G2).
Signal
(A1)
• Color (colour) bar signal [SECAM]
Mode
(B)
• EE
Equipment
(C)
• Oscilloscope
Measuring point (D)
• CN1601 Pin 7
Adjustment part
(F1)
• VR1602 (B-Y ADJ)
(F2)
• VR1601 (R-Y ADJ)
Specified value
(G1)
• 460 ± 20 mVp-p : VR3506 (B-Y)
(G2)
• 620 ± 20 mVp-p : VR3505 (R-Y)
GREEN
H.rate
YELLOW
BLUE
MAGENTA
Specified
value (G2)
Specified
value (G1)
Fig. 3-6-1 Colour difference level