![Philips Lytespan 24MHT4RNF Specification Download Page 2](http://html.mh-extra.com/html/philips/lytespan-24mht4rnf/lytespan-24mht4rnf_specification_310339002.webp)
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • C0510
Lytespan
®
Track Lighting System
24MHT4RNF
Page 2 of 2
Mini HID T4 GU6.5, BT PGJ5 Narrow Flood Reflector
Job Information
Type:
Aiming Angle:
0°
30° Horizontal
30° Vertical
45° Vertical
L
Beam length
D
Distance
W
Beam Width
A
Aiming Angle
C
Distance to center beam
FC
Footcandles
L
and
W
are the outer points where the candle
power drops to 50% of the maximum.
FC
are the
initial footcandles at the center of the beam.
Lamp data shown is typical. Consult lamp
manufacturers for availability and performance.
CBCP = Center Beam Candle Power.
Lamp
Beam Spread
CBCP
Rated
(To 50% CBCP)
Life (Hrs.)
D
FC
L
W
6
112
2.4
2.4
8
63
3.3
3.3
10
40
4.1
4.1
12
28
4.9
4.9
D
FC
C
L
W
6
3.5 72 3.3 2.8
8
4.6 41 4.4 3.8
10 5.8 26 5.5 4.7
12 6.9 18 6.6 5.6
D
FC
C
L
W
2
3.5 126 3.7 1.6
3
5.2 56 5.6 2.4
4
6.9 31 7.4 3.3
5
8.7 20 9.3 4.1
D
FC
C
L
W
3
3.0 158 2.5 1.7
4
4.0 89 3.4 2.3
5
5.0 57 4.2 2.9
6
6.0 39 5.1 3.5
20W T4
4017
12,000
8109
24MHT4RNF
23°
20W BT-5
5408
12,000
8111
24MHT4RNF
22°
D
FC
L
W
6
150 2.3
2.3
8
85
3.1
3.1
10
54
3.9
3.9
12
38
4.7
4.7
D
FC
C
L
W
6
3.5 98 3.1 2.7
8
4.6 55 4.2 3.6
10 5.8 35 5.2 4.5
12 6.9 24 6.3 5.4
D
FC
C
L
W
2
3.5 169 3.5 1.6
3
5.2 75 5.3 2.3
4
6.9 42 7.0 3.1
5
8.7 27 8.8 3.9
D
FC
C
L
W
3
3.0 212 2.4 1.6
4
4.0 120 3.2 2.2
5
5.0 76 4.0 2.7
6
6.0 53 4.8 3.3
35W BT-5
9153
9,000
8112
24MHT4RNF
22°
D
FC
L
W
8
143
3.1
3.1
10
92
3.9
3.9
12
64
4.7
4.7
14
47
5.4
5.4
D
C
FC
L
W
6
3.5 165 3.1 2.7
8
4.6 93 4.2 3.6
10 5.8 59 5.2 4.5
12 6.9 41 6.3 5.4
D
C
FC
L
W
2
3.5 286 3.5 1.6
3
5.2 127 5.3 2.3
4
6.9 72 7.0 3.1
5
8.7 46 8.8 3.9
D
C
FC
L
W
3
3.0 360 2.4 1.6
4
4.0 202 3.2 2.2
5
5.0 129 4.0 2.7
6
6.0 90 4.8 3.3
Note:
For Champagne Bronze (CCZ), multiply FC values by 0.64.
For Incandescent Warm (WRM), multiply FC values by 0.85.