Page 1: ...Monochrome Cameras LTC 0140 LTC 0142 LTC 0143 Philips Communication Security Systems Eng ...

Page 2: ...rce and uneven surfaces may cause the appliance and cart combination to overturn 9 Ventilation Openings in the enclosure if any are provided for venti lation and to ensure reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered This unit should not be placed in a built in installation unless proper ventilation is provided or the manufacturer ...

Page 3: ...e following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the unit c If the unit has been exposed to rain or water d If the unit does not operate normally by following the operat ing instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in da...

Page 4: ... that interference will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and r...

Page 5: ...Fig 1 5 ...

Page 6: ...6 Fig 2 ...

Page 7: ...Fig 3 mm inches 7 ...

Page 8: ...rating and mainte nance servicing instructions in the literature accompanying the appliance Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Power disconnect Units with or without ON OFF switches have power supplied to the unit whenever the power cord is inserted into the power source The power ...

Page 9: ...ow Voltage a c 12 28 12 28 Mains Voltage Class II 85 265 120 10 20 CCIR 625 lines 50 Hz Yes Yes EIA 525 lines 60 Hz Yes Yes Note With isolation transformer Use Pin 1 as common Fig 2 Maximum start up current 400mA Low Voltage Connection Fig 2 n LTC 10 LTC 20 Terminal block pin 1 Supply Reference for line lock Terminal block pin 2 Supply Mains Connection Fig 2 n LTC 50 Fitted 2 pole Euro connector B...

Page 10: ... F2 0 Lens connector LTC 0140 only Fig 1 B The 4 pin lens socket located on the back is connected as follows Pin Signal Remark 1 Control Feedback 2 Control Feedback 3 Drive Max 40 mA 4 Drive GND Adjustments MAINS LINE LOCK Fig 2 item A Phase BLC Fig 1 item A Press to advance PHASE Press to decrease PHASE Range is from 0 to 300 Default camera is delivered with PHASE set to 0 10 L L 1 0 ON OFF PHASE...

Page 11: ... 0140 only To fit the lens hold the camera head with its front facing downwards and then a Remove the dust cap from the lens mount b Ensure that the back focus lever A is loose and screw the lens into the CS mount c Set the lens distance to infinity d Screw the lens in or out until the picture is sharp object distance should be more than 15m e Tighten the lens by locking the back focus lever A CAU...

Page 12: ... 000 sec Video output 1 Vpp VBS into 75 Ω Video connector BNC Power consumption 3W Mains Line Lock Lock range 1 of mains frequency Material Polycarbonate color gray finish Dimensions See Fig 3 Weight Approx 200 g 0 44 lb Environmental Temperature range Operating 10 C to 55 C 14 F to 131 F Storage 40 C to 70 C 40 F to 158 F Air pressure 70 kPa to 110 kPa Relative humidity 5 to 93 Shock IEC68 2 27 E...

Page 13: ...3922 988 85013 98 35 1998 Philips Electronics N V Data subject to change without notice ...