Philips Louver IC Series Specifications Download Page 2

Louver

IC Series

Page 2 of 2

2' x 2' Recessed Fluorescent, 3" 9 or 16 Cell Parabolic Louver

Static, 2-6" U Lamp T8

Options/Accessories

Plaster Frame

: Catalog Number:

PF24

.

Radio Interference Filter

: To order one RIF per fixture; SUFFIX:

R

.

To order one RIF per ballast; SUFFIX:

B

.

Fusing

: Internal fast-blow fusing. SUFFIX

A

. Internal slow-blow fusing. SUFFIX

C

.

Electrical Wiring Options

: Consult factory.

Drywall Kit

: Order Catalog Number:

FK92X4

. (Request Folio OA30-10 Rev. A).

Chicago Plenum

: SUFFIX:

C

.

Specifications

Performance

: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance

80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To prevent glare the VCP shall
be not less than 63 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 2502 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 67.2%.

Specifications (continued)

Materials

:

Chassis parts

are die-formed code gauge cold rolled steel. Housing is ribbed for

rigidity with side rails hemmed over and housing ends turned-in for safe handling.

Louver

is pre-

anodized aluminum.

Finish

:

Chassis exterior

–black baked polyester enamel.

Cavity

–white baked polyester enamel

minimum 86% reflectance. Rust preventative undercoating.

Louver

–low iridescence semi-specular

anodized vertical grain aluminum reflector sheet is standard.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of

ballast, use wire suitable for at least 90°.

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp.
Manage in accord with Disposal Laws.
See: www.lamprecycle.org

IC Series:

Recessed

Parabolic

suitable for

Thermal

Insulation

Contact

S

Body Style:

S

=Static

2

Fixture

Width

2

Lamp

Quantity

2

=2 lamps

6U

Ballast Type:

<

20THD

<

10THD

1-2 Lamp Elec. T8

SO *

H

I

*

LOL T8 Dimming

PS

*Instant Start Standard
Other dimming options, consult factory.

NOTE:

For

T8 UNV

, you must use

H

I

Ballast Code.

Ordering Information

Explanation of Catalog Number. Example: ICS2G9LS26UUNVHI

Ceiling Type:

G

= Grid

(lay-in T bar)

T

= Slot grid

Number of

Cells:

9

=3 rows

of 3

16

=4 rows

of 4

Louver Finish:

L

= Low iridescence

Semi-specular
(standard)

P

=Low iridescence

Specular

W

=White Baked

Enamel

S

Single "V"

Reflector

Voltage:

120, 277 or

UNV

=120-277

Lamp Type/

Fixture Length:

6"U T8

2 Lamp Only

(Nominal 24")

IC

Standard IC Parabolic

IY

For NYC Code – I.B.E.W. Manufactured

0.0

45.0

90.0

FLUX

0

1552

1552

1552

5

1545

1546

1556

147

15

1465

1501

1530

423

25

1341

1353

1369

625

35

1165

1132

1146

716

45

943

905

1090

743

55

677

744

966

683

65

214

286

301

271

75

23

26

27

30

85

4

5

4

5

90

0

0

0

Model No. ICS2G9LS26U120SO

LER = FP - 53.4

IW - 57.2

BF - 0.87

Comparative yearly lighting energy cost per

1000 lumens = $4.49

Report Number: G00027
Catalog Number: ICS2G9LS26U120S0
Lamp: (2) F32 T8
Luminaire: IC 2' X 2' Troffer with 3X3

Spectular Louver

Ballast: M2-RN-T81LL-D-120
Report is based on 2750 Lumens per lamp.
Efficiency: 66.2%
CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.2

Shielding Angles:

23

23

Plane:

0-Deg

90-Deg

Luminous Length:

21.720

21.720

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

4686.

4497.

5416.

55

4147.

4557.

5917.

65

1779.

2378.

2502.

75

312.

353.

367.

85

161.

202.

161.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1

73 71 69 67 65 63 64 63 61

2

68 63 59 60 57 54 57 55 53

3

62 56 51 53 49 46 51 48 46

4

57 50 45 48 43 40 46 43 40

5

53 45 40 43 38 35 42 38 35

6

49 41 35 39 34 31 38 34 31

7

45 37 31 35 31 27 35 30 27

8

42 34 28 32 28 25 32 27 24

9

40 31 26 30 25 22 29 25 22

10 37 29 24 28 23 20 27 23 20

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1195

21.7

32.8

0

0-

0

40

1911

34.7

52.5

0

0-

0

60

3336

60.7

91.6

0

0-

0

90

3643

66.2

100.0

90-180

000

0

0.0

00

0.0

0

0-180

3643

66.2

100.0

ZONAL LUMEN SUMMARY

Mounting Height

Lengthwise

Crosswise

Room

Luminaires

Luminaires

Size

0 Deg Plane

90 Deg Plane

8.5 10 13 16

8.5 10 13 16

30x30

75 69 60 57

72 66 57 53

40x40

80 74 67 60

77 71 64 57

60x30

79 74 67 61

76 71 64 58

60x60

82 78 72 65

80 75 70 63

100x100

85 82 78 72

84 80 76 70

TYPICAL V.C.P.'s

Options:

Lamps
Flex
EM Pack
Fuse

(Consult your

representative)

-

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

08/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 7/Folio Q80-15 Rev. A

Reviews: