background image

Alter 

Concept SR T5

Page 2 of 2 

2' x 2' semi-recessed direct/indirect fluorescent

Job Information 

Type:

Lightolier is a Philips group brand

Lightolier 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2008 Philips Group • 

QCH2x2PFOS.pdf

Canlyte 

www.canlyte.com

3015 Louis-Amos, Lachine, Québec  H8T 1C4 • (514) 636-0670 • (514) 636-0460

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

  0 

1185 

1185 

1185 

1185 

1185

  5 

1175 

1185 

1177 

1176 

1177

10 

1153 

1156 

1162 

1166 

1169

15 

1133 

1137 

1153 

1152 

1168

20 

1089 

1094 

1108 

1122 

1133

25 

1040 

1048 

1067 

1092 

1105

30 

977 

994 

1019 

1050 

1074

35 

919 

925 

966 

1007 

1025

40 

841 

851 

904 

955 

988

45 

757 

775 

830 

903 

939

50 

654 

683 

768 

842 

875

55 

553 

591 

692 

770 

804

60 

452 

496 

610 

686 

723

65 

353 

409 

518 

591 

624

70 

267 

327 

417 

489 

529

75 

179 

228 

317 

374 

396

80 

 99 

134 

184 

201 

198

85 

 42 

45 

45 

63 

69

90 

 0 

 0 

 0 

 0

COEFFICIENTS OF UTILIZATION

ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20

  

 

 

 

  

 

 

  

 

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

  0  .69  .69  .69  .69  .68  .68  .68  .68  .65  .65 

.65

  1  .63  .61  .58  .56  .62  .60  .57  .55  .57  .55 

.53

  2  .58  .53  .50  .46  .57  .52  .49  .46  .50  .47 

.45

  3  .53  .47  .42  .38  .51  .46  .42  .38  .44  .41 

.37

  4  .49  .42  .37  .33  .47  .41  .36  .33  .40  .35 

.32

  5  .45  .37  .32  .28  .43  .36  .32  .28  .35  .31 

.28

  6  .41  .33  .28  .24  .40  .33  .28  .24  .32  .27 

.24

  7  .38  .30  .25  .21  .37  .29  .24  .21  .28  .24 

.21

  8  .35  .27  .22  .18  .34  .26  .22  .18  .26  .21 

.18

  9  .32  .24  .19  .16  .31  .24  .19  .16  .23  .19 

.16

 10  .30  .22  .17  .14  .29  .22  .17  .14  .21  .17 

.14

     

 

 

 

 

 

 

DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES

LuMINAIRE INPuT WATTS = 70.7

Room Cavity Ratio

ZONE 

LUMENS 

% LAMP 

% LUMINAIRE

0-30 

928 

14.73 

25.31

0-40 

1532 

24.33 

41.79

0-60 

2788 

44.26 

76.04

0-90 

3667 

58.21 

100.00

40-90 

2134 

33.88 

58.21

60-90 

 878 

13.95 

23.96

90-180 

.00 

.00

0-180 

3667 

58.21 

100.00

DISTRIBUTION

CANDLEPOWER CURVE 2FT

Performance

CANDLEPOWER

REPORT NO: LSCB634
CAT. NO: QCH2GPFOS2FT

2 40W TT5 Compact Fluorescent Lamps at 3150 lumens. 

Efficiency: 58.2%

 

Candela at Nadir: 1185cd

90°

90°

180°

400

800

1200       

 

 

 

  

ZONE  

 

 

 

 

 

DEG   

 

ALONG  22.5 

45 

67.5 

ACROSS

 

 

 

 

 

 

  0  

791 

791 

791 

791 

791

  5 

785 

785 

789 

789 

787

10 

775 

780 

779 

786 

787

15 

756 

760 

771 

771 

775

20 

737 

739 

744 

751 

766

25 

700 

705 

716 

733 

740

30 

659 

676 

684 

705 

712

35 

617 

632 

654 

670 

691

40 

566 

583 

616 

634 

651

45 

504 

527 

563 

590 

606

50 

442 

463 

507 

549 

574

55 

377 

411 

459 

518 

534

60 

309 

343 

409 

458 

478

65 

238 

287 

354 

384 

394

70 

181 

224 

278 

308 

327

75 

129 

165 

203 

223 

235

80 

68 

93 

112 

112 

106

85 

29 

28 

36 

45 

46

90 

 0 

16 

18

COEFFICIENTS OF UTILIZATION

ZONAL CAvITY METHOD * EFFECTIvE FLOOR CAvITY REFLECTANCE = .20

  

 

 

 

  

 

 

  

 

  

 

     80  

  

               70   

  

 

50

Wall Reflectance

 

70  50  30  10  70  50 

30  10  50  30 

10

  0  .83  .83  .83  .83  .81  .81  .81  .81  .77  .77 

.77

  1  .76  .73  .70  .67  .74  .71  .69  .66  .68  .66 

.64

  2  .69  .64  .59  .55  .67  .62  .58  .54  .60  .56 

.53

  3  .63  .56  .50  .46  .61  .55  .50  .46  .53  .48 

.45

  4  .58  .50  .44  .39  .56  .49  .43  .39  .47  .42 

.38

  5  .53  .44  .37  .33  .51  .43  .37  .33  .41  .36 

.32

  6  .48  .39  .33  .28  .47  .38  .32  .28  .37  .32 

.28

  7  .44  .35  .29  .25  .43  .34  .29  .24  .33  .28 

.24

  8  .41  .31  .25  .21  .40  .31  .25  .21  .30  .25 

.21

  9  .38  .28  .22  .18  .37  .28  .22  .18  .27  .22 

.18

 10  .35  .26  .20  .16  .34  .25  .20  .16  .24  .19 

.16

     

 

 

 

 

 

 

DETERMINED IN ACCORDANCE WITH CuRRENT IES PuBLISHED PROCEDuRES

LuMINAIRE INPuT WATTS = 51.6

Room Cavity Ratio

ZONE 

LUMENS 

% LAMP 

%LUMINAIRE

0-30 

624 

17.73 

25.49

0-40 

 1031 

29.31 

42.14

0-60 

 1872 

53.20 

76.49

0-90 

 2448 

69.56 

100.00

40-90 

1416 

40.25 

57.86

60-90 

 575 

16.35 

23.51

90-180 

.00 

.00

0-180 

2448 

69.56 

100.00

DISTRIBUTION

CANDLEPOWER CURVE 224

Performance

CANDLEPOWER

REPORT NO: LSCD081
CAT. NO: QCH2GPFOS224

2 24W T5HO Fluorescent Lamps at 1760 lumens. 

Efficiency: 69.6%

 

Candela at Nadir: 791cd

90°

90°

180°

400

800

1200       

 

Reviews: