SECTION 6:  HEALTH HAZARD DATA

WARNING

:  THIS LAMP EMITS SHORTWAVE ULTRAVIOLET RADIATION WHICH IS

HARMFUL TO SKIN AND EYES AND CAN CAUSE SERIOUS SKIN BURNS AND EYE
INFLAMMATION.  USE ONLY IN EQUIPMENT SPECIFICALLY DESIGNED TO
REDUCE THE RISK OF PERSONAL INJURY AND PROPERTY DAMAGE RESULTING
FROM ARC TUBE RUPTURE AND FROM ULTRAVIOLET RADIATION.  IT IS
RECOMMENDED THAT THIS LAMP BE USED IN FIXTURES HAVING A SAFETY
INTERLOCK SWITCH.  LEAD IODIDE IS NOT LISTED AS A CARCINOGEN BY IARC,
NTP, OR OSHA.
------------------------------------------------------------------------------------------------------------------
FIRST AID:  If exposure to ultraviolet radiation occurs, it is recommended that an
opthamologist be consulted.

SECTION 7:  PRECAUTIONS FOR SAFE HANDLING AND USE

WASTE DISPOSAL METHOD: The lamp contains a small amount of mercury - together with a
small amount of lead iodide.  Under the toxicity characteristic leaching procedure (TCLP)
promulgated by the United States E.P.A. tests of used or spent high intensity discharge lamps
indicate that these lamps generally are considered to be hazardous  when discarded.  (Fed. Reg.
7/27/94.) EPA has issued the Universal waste Rule for lamps which fail the TCLP (Fed Reg
7/6/99).  More than thirty States now manage lamps under this Rule. The UWR requires
recycling or hazardous waste disposal of those lamps which fail TCLP. There are some
exemptions which depend on your status, volume and or location. Check with your State
Authorities for information to ensure proper waste disposal practice.

A division of

Philips Electronics North America Corporation

200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
Tel: 732.563.3000

L 1250 - HPM, L 1261 - HPA

Summary of Contents for L 1250 - HPM

Page 1: ...63 3197 Environmental Other Information Calls 800 PLC BULB SECTION 2 HAZARDOUS INGREDIENTS OSHA PEL ACGIH TLV Mercury 7439 97 6 1mg m3 Ceiling 025mg m3 8hr TWA 02 Lead Iodide 10101 63 0 05mg m3 1mg m_ 02 Gallium Iodide 13450 91 4 NONE ESTABLISHED 02 Cobalt 7440 48 4 1 mg m_ NONE EST D 02 Krypton 85 HPM less than 15 nCi HPA less than 50 nCi HPM Only HPA Only A division of Philips Electronics North ...

Page 2: ... AND OR SURROUNDING ENVIRONMENT COULD OCCUR THEREBY CREATING A RISK OF PERSONAL INJURY PROPERTY DAMAGE OR FIRE SECTION 5 REACTIVITY DATA Stability Envelope is stable Incompatibility Envelope can be affected by oils and fats deposited on surface from fingers Handling of envelope should only be done with gloves While the amount of lead iodide is small and exposure occurs only if the lamp is broken t...

Page 3: ... contains a small amount of mercury together with a small amount of lead iodide Under the toxicity characteristic leaching procedure TCLP promulgated by the United States E P A tests of used or spent high intensity discharge lamps indicate that these lamps generally are considered to be hazardous when discarded Fed Reg 7 27 94 EPA has issued the Universal waste Rule for lamps which fail the TCLP F...

Page 4: ...ing lamp to operate until it fails is not recommended and may increase the risk of inner arc tube rupture 5 Use within voltage limits recommended by ballast manufacturer Do not operate lamp at higher than specified power 6 The permissible maximum operating temperatures e g the pinch temperatures the tempera ture of the bulb wall as indicated on the product leaflet may not be exceeded 7 Lamp should...

Page 5: ...ire D008 RCRA classification If state adopts universal waste rule spent lamps can be shipped using common carrier and bills of lading Contact your state environmental agency for guidance Prepared 8 9 95 S21 95001 A division of Philips Electronics North America Corporation 200 Franklin Square Drive P O Box 6800 Somerset NJ 08875 6800 Tel 732 563 3000 ...

Reviews: