Page 1: ...Philips Home Control Confidential Philips Home Control 2013 Page 1 of 14 Manual of KWR101830 01B KWR101830 01BS KWR101830BU ...

Page 2: ...ordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the ...

Page 3: ...ual button entry RC and KWR Number of keys 38 for KEYBOARD 18 for RC Total 56 keys 4 main functions Remote Control Mouse Cursor Control Qwerty KEYBOARD for text entry and downstream data transfer 128k Flash for handling RF functions 6 axis motion pointing IR Learn using Data Flash IR Database IR uses Flash chip Low voltage alert through LED blinks Works with USB Receiver dongle OVU810006 ...

Page 4: ...KWR101830 01B Manual Draft Version Status Draft For Review Page 4 of 14 Philips Proprietary Confidential Philips Home Control Company Restricted 1 2 Product Picture for illustration only ...

Page 5: ...ired receiver will be retained 2 Same receiver o Previously paired information of the same receiver shall first be erased from the RC before pairing process starts o If the pairing process fails or pairing timeout occurs the previously paired receiver will not be retained At any one time Only one RC is allowed to be in pairing mode i e no concurrent pairing is allowed Each RC can only work with on...

Page 6: ...VE SLEEP User action Remote Control action No key press for less than 15 seconds RF goes to SLEEP In SLEEP mode all LEDs are OFF No motion senses for about 15 seconds RF goes to SLEEP In SLEEP mode all LEDs are OFF 2 6 RF Auto Connection When the RC wakes up or resumes from SLEEP mode or come back within range of a powered on paired receiver the RF link will be reconnected automatically No RF re p...

Page 7: ...p a command will be sent from the RC 3 2 Remote IR Keys TV POWER VOL VOL MUTE and AV are IR command keys With RC side faced up and in a portrait orientation pressing these buttons will fire the respective IR codes from the IR LED of the remote control 3 3 Remote RF keys Remote RF keys will be sent in the form of HID Keyboard keys 3 4 Motion Control Mouse Mode Mouse mode allows user to use the 3 D ...

Page 8: ... be held by both hands and used in landscape orientation The keyboard also supports secondary keys by using FN CAPS or Alt Gr this allows the keyboard to support uppercase characters symbols and digits with the limited number of Qwerty keys There are 2 ways of activating secondary keys 1 Press and release FN or CAPS or Alt Gr key followed by pressing another key For example press FN then Q will se...

Page 9: ... code transmission 1 short blink in red each time a valid key is pressed TV POWER Low battery warning 2 long blinks in red each time a RC key is pressed TAB Low battery warning 2 long blinks in amber each time a KEYBOARD key is pressed SYSTEM POWER Mouse Left Click 1 short blink in red each time Mouse Left Click is pressed SYSTEM POWER Definition of Error in setup mode Key press and hold 30 second...

Page 10: ...5 User can learn other keys by repeating Steps 2 to 4 6 Press BACK Key in IR Learning mode and will exit to normal mode Error handling 1 If a wrong key is pressed at Step 2 SYSTEM POWER LED will fast blink 3 times and go back to Step 2 2 If any stuck key s occurs in any of the learning sequence SYSTEM POWER will fast blink 3 times exit IR Learning mode and enter Stuck Key mode Please take note of ...

Page 11: ...letes for the codeset under scan the TV POWER LED will turn off and no new IR command will be sent over the next 1 5 seconds approximately If the TV does not turn off the user will need to keep pressing the UP key and the remote control will then try the next universal codeset in the list 4 When the TV turns off the user shall release the UP key to stop IR transmission The user can now try pressin...

Page 12: ... Step 3 the TV POWER LED will give 10 fast blinks to indicate End Of Search 4 When database scanning is in progress RF functions are disabled e g keys on KEYBOARD side are locked Only after exiting from Database Programming mode the RF functions are resumed 5 The learn codes or default IR codes RC6 Mode 6A underlying each of IR keys will be replaced with the IR codes from the valid codeset ID bein...

Page 13: ...ill pressed the RC will not transmit code or do any action After release and then press any keys that have an alternate function on the same key e g Q key shares the same as numeric 1 key the RC will transmit numeric 1 code E g FN key Q key Numeric 1 key is transmitted FN key A key Symbol key is transmitted The same is true for CAPS and Alt Gr keys For example after release of the CAPS key an alph...

Page 14: ...tery power will be in 2 stages LED blinking is dependent on the remote control side red LED for RC side amber LED for KEYBOARD side Note The Remote will only check for low voltage after it goes to sleep and wakeup OR every 3s interval while the Remote is active 1 Stage 1 Working voltage 4 8V to 3 3V All keys and functions will work as normal 2 Stage 2 Very Low voltage 3 3V and below Very Low volta...