background image

3 - 4

Quick Start Guide - IR Dongle v2.0

December 2018

IR Dongle v2.0

Battery Replacement

The battery can be replaced by opening the IR dongle by  
2 screws. Type of battery: CR2032. Follow the steps shown 
below to replace the battery.
Recommended suppliers:
• Panasonic
• Varta 
• Energizer

1

   Disassemble the IR Dongle and replace the battery  

with  identical  polarity  as  shown  on  Figure  1.                                               

2

   Once, the battery is replaced, connect the part with  

the bottom cover. Observe the orientation of (1).

Figure 1 
Disassemble of IR Dongle                                                         

Figure 2
Assemble the parts 

3

   Assemble both parts. Make sure that the sides are well 

attached  and  fit  the  matching  screw  holes  together..                                               

4

   Screw up the screws in a clockwise direction.

Figure 4
Attach the screws  

Figure 3 
Bring together  
the two parts                                                         

Summary of Contents for IR dongle

Page 1: ...e at the target luminaire using the IR dongle and check the light behavior according to steps in the App to confirm the command gets executed light dimmed light blinks twice etc Invert Signal in the Preferences within app when the LED blinks 6 times Note Remember to switch off the LEDs when not in use to save battery and for longer lifetime Working with Philips Field Apps You must first register f...

Page 2: ...witch 2 LEDs are available for use depending upon the application An LED on top side for long distance communication ideal for highbay industry application upto 16m An LED on side for short distance communication ideal for office applications upto 8m IR Dongle v2 0 Signal LED red in colour Long Distance highbay Short Distance office Short Distance office OFF Long Distance highbay ...

Page 3: ...1 Disassemble the IR Dongle and replace the battery with identical polarity as shown on Figure 1 2 Once the battery is replaced connect the part with the bottom cover Observe the orientation of 1 Figure 1 Disassemble of IR Dongle Figure 2 Assemble the parts 3 Assemble both parts Make sure that the sides are well attached and fit the matching screw holes together 4 Screw up the screws in a clockwis...

Page 4: ...any action in reliance thereon The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N V All other trademarks are owned by Signify Holding or their respective owners 01 2019 Data subject to change ...

Reviews: