DISASSEMBLY PARTS LIST HQ-T 764 

to replace 

ON / OFF KNOB (8)

remove 

SCREW A

 COVER 

(7)

Never use again a deformed housing clamp (3).

Before reassembling the battery holder, make sure 
that the internal wiring is guided as shown in fi gure 1. 

After the product has been repaired, it should 
function properly and has to meet the safety 
requirements as laid down and offi cally established at 
this moment.

to replace 

SPRING ZOOM RING (6)

remove 

COMB (1)

 SCREW 

A

 COVER 

(7)

 

COMB HOLDER (4)

 

ZOOM RING (5)

 pos 

description 

service code

  1 

comb 

4203 035 76450

  2 

cutter 

4203 035 76420

  3 

housing clamp 

4203 035 76410

  4 

comb holder 

4203 035 76400

  5 

zoomring 

4203 035 76350

  6 

spring zoom ring 

4203 035 71380

  7 

cover 

4203 035 76700

  8 

on/off knob 

4203 035 76470

  9 

PCB 

4203 035 76510

  10 

battery NiCd 

4822 138 10336

  11 

cleaning brush 

4822 479 30183

  12 

adapter NiCd USA 

4203 035 76540

 

 

adapter NiCd CND 

4203 035 76530

 

 

adapter NiCd EURO 

4203 035 76520

 

 

adapter NiCd UK 

4203 035 76550

to replace 

BATTERY (10)

 PCB 

(9)

remove 

COMB (1)

 CUTTER 

(2)

 

HOUSING CLAMP (3)

 COMBHOLDER 

(4)

 SCREW 

A

 COVER 

(7)

 

ZOOM RING (5)

 CAP 

B

fi gure 1