105

100

95

90

85

80

75

70

65

60

Relativ

e

Light

Output

(%)

Ambient Temperature ˚C

0˚C

10˚C

20˚C

30˚C

40˚C

50˚C

60˚C

70˚C

80˚C

32˚F

50˚F

68˚F

86˚F

104˚F

122˚F

140˚F

158˚F

176˚F

Performance

(Relative Light Output vs.Temperature)

Philips T5VHO Extreme Temperature Lamps vs. Standard F54T5 Lamps

Philips T5 VHO Extreme Temperature lamps featuring ALTO

®

Lamp Technology

Lamp Ordering, Electrical and Technical Data

Color

Nom.

Rated Avg. Life (Hrs.)

1

Approx.

Product

Ordering

Pack.

Temp.

Length

3 Hr.

12 Hr.

Initial

Design

Lumen

Number

Code

Watts

Qty.

(Kelvin)

(In.)

Start

2

Start

3

Lumens

4

Lumens

5

CRI

Maint.

21771-1

F95T5/835/VHO/A/ALTO

95

40

3500

46

25,000

35,000

7200

6900

85

90%

21772-3

F95T5/841/VHO/A/ALTO

95

40

4100

46

25,000

35,000

7200

6900

85

90%

1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not.

2) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
3) Average life under engineering data with lamps turned off and restarted once every 12 operating hours on a programmed start ballast. Lamp life is appreciably longer if lamps are started less frequently.
4) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a high frequency reference ballast under

standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.
The ballast factor is a multiplier applied to the designated lamp lumen output.

5) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under

standard laboratory conditions.

This lamp is better for the environment because of its reduced mercury content. All Philips ALTO

®

lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and

local regulations.

Note:T5 VHO lamps have new miniature flat pin bases which require new GX5 sockets.
Above specifications subject to change without notice.

Rated Average Life in Hours

Rated Average Life in Hours

BASED ON 3 HOURS PER START

2

25,000

BASED ON 12 HOURS PER START

3

35,000

Programmed Start Ballast

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

Rated Average Life

1

Philips T5 VHO Extreme Temperature Lamps

90% Lumen Maintenance

Philips T5 VHO Extreme Temperature Lamps

Footnotes from front page:

* 90% lumen maintenance at 17,500 hours for the T5 VHO lamp compared to 65% lumen maintenance at 8000 hours for the MH400/U lamp.

‡ 458 system watts (MH400/U) – 418 system watts (T5 VHO) = 40 system watts.

35,000 rated average life (T5 VHO at 12 hours per start) compared to 20,000 rated average life (MH400/U at 13 hours per start)

** For example, with 7200 initial lumens, you only need (4) 95W T5 VHO lamps instead of (6) T5 54W HO lamps when replacing a standard 400W HID System.

** For example, with 7500 initial lumens, you only need (4)

95W T5 VHO lamps instead of (6) T5 54W HO lamps when replacing a standard 400W HID System.

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

100%

98%

96%

94%

92%

90%

88%

100%

98%

96%

94%

92%

90%

88%

Lamp Operating Hours

Lamp Operating Hours

Light

Output

(%)

Light

Output

(%)

New P-5904-A T5 VHO Prod Bulletin.qxd:Layout 1

9/9/08  6:08 PM  Page 2

Summary of Contents for HO

Page 1: ...g light output due to hot or cold temperatures Provides high light output even in spaces without climate control Lumen output is 90 from 65 F to 170 F 20 C to 75 C due to amalgam technology More light over the life of the lamp than a standard 400W HID system Operates on existing electrical system 277V 480V input voltage range eliminates the need for rewiring your electrical system Reduce total cos...

Page 2: ...hey are informed of the designated lamp The ballast factor is a multiplier applied to the designated lamp lumen output 5 Design lumens are the approximate lamp lumen output at 40 of the lamp s rated average life This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions This lamp is better for the environment because of its red...

Page 3: ...tronic type and operate above 40 kHz to avoid interference with infrared control systems and eliminate visible flicker 2 11The electronic ballast shall comply with ANSI C82 11 where applicable 2 12 The electronic ballast shall provide transient immunity as specified in ANSI C62 41 2 13 The electronic ballast shall provide end of life protection circuitry 2 14 The electronic ballast shall have a mi...

Page 4: ...ormer com 2008 Philips Lighting Company A Division of Philips Electronics North America Corporation All rights reserved Reproduction in whole or part is prohibited without the prior written consent of the copyright owner The information presented in this document does not form part of any quotation or contract is believed to be accurate and reliable and may be changed without notice No liability w...

Reviews: