Philips T5 VHO Extreme
Temperature System

Ideal for high-bay
applications without
climate control

T5 COLLECTION

† This lamp is better for the environment because of

its reduced mercury content. All Philips ALTO

®

lamps give you end-of-life options which can simplify
and reduce your lamp disposal costs depending on
your state and local regulations.

Lower the costs of your ceilings

With the

Philips T5 VHO Extreme Temperature System,

you can use T5 lamps in high-bay applications without
sacrificing light output due to hot or cold temperatures.

Provides high light output even in spaces without climate control

• Lumen output is >90% from 65˚F to 170˚F (20˚C to 75˚C) due to amalgam technology
• More light over the life of the lamp than a standard 400W HID system

*

Operates on existing electrical system

• 277V– 480V input voltage range eliminates the need for rewiring

your electrical system

Reduce total cost of ownership (TCOO) when compared to a
standard HID 400W system

• Reduced energy costs — save up to 40 system watts

• Reduced maintenance costs — up to 75% longer lamp life

which extends

the relamping cycle

• Reduced costs since less lamps are needed to meet lumen requirements

**

(*, ‡,

, ** See page 2 for footnotes)

New P-5904-A T5 VHO Prod Bulletin.qxd:Layout 1

9/9/08  6:08 PM  Page 1

Summary of Contents for HO

Page 1: ...g light output due to hot or cold temperatures Provides high light output even in spaces without climate control Lumen output is 90 from 65 F to 170 F 20 C to 75 C due to amalgam technology More light over the life of the lamp than a standard 400W HID system Operates on existing electrical system 277V 480V input voltage range eliminates the need for rewiring your electrical system Reduce total cos...

Page 2: ...hey are informed of the designated lamp The ballast factor is a multiplier applied to the designated lamp lumen output 5 Design lumens are the approximate lamp lumen output at 40 of the lamp s rated average life This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions This lamp is better for the environment because of its red...

Page 3: ...tronic type and operate above 40 kHz to avoid interference with infrared control systems and eliminate visible flicker 2 11The electronic ballast shall comply with ANSI C82 11 where applicable 2 12 The electronic ballast shall provide transient immunity as specified in ANSI C62 41 2 13 The electronic ballast shall provide end of life protection circuitry 2 14 The electronic ballast shall have a mi...

Page 4: ...ormer com 2008 Philips Lighting Company A Division of Philips Electronics North America Corporation All rights reserved Reproduction in whole or part is prohibited without the prior written consent of the copyright owner The information presented in this document does not form part of any quotation or contract is believed to be accurate and reliable and may be changed without notice No liability w...

Reviews: