PARTS LIST + DISASSEMBLY ADVICE STAND
Pos
Description
Service Nummer
Stand rubber feet
Rubber feet above screw
Complete tray
Safety cab
Rubber ring in fi lling hole
21
22
23
24
25
9965 000 01692
9965 000 01702
9965 000 01861
9965 000 01862
9965 000 01866
Cover
Rubber feet boiler
Boiler complete
Locked insert
Bottom housing
26
27
28
29
30
9965 000 01892
4822 462 71999
9965 000 01868
9965 000 01788
9965 000 01789
Filter
Switch
Electro valve
Cordset Italian
plug
Cordset Europe
plug
31
32
33
34
9965 000 01790
9965 000 01791
4822 218 11561
9965 000 01792
9965 000 01793
Steam dial
Steam regulator
Boiler empty lamp
Boiler ready lamp
GBR, FRA, DEU, NLD,
ESP, PRT, ITA
36
37
38
39
DFU
9965 000 01899
9965 000 01900
9965 000 01901
9965 000 01902
4222 001 92201
OPEN THE STAND
D
Below rubber feet
remove SCREW D (1 x)
E
E
E
remove SCREW E (3 x)
remove LOCKED INSERT 29
NOTE:
OPEN NOW THE STAND.
DON’T WORRY IF THE SNAPS AT THE SIDE WILL BE
BROKEN.
THEY ARE ONLY FOR THE ASSEMBLY.
THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.
ADJUSTMENT AND CONTROLS
– To avoid leakage of the sealings and damage to the
components in and on the boiler, NEVER clean
the boiler with vinegar, a descaling agent or other
chemicals.
– The boiler doesn’t contain serviceable parts.
Never disassemble the boiler body and /or com-
ponents on and in the boiler.
– ALWAYS REPLACE THE BOILER ( 28 ) WHEN:
*
the mechanical safety valve ( 24 ) has been
activated.
*
the boiler thermostat or hand - resettable
safety thermostat are open, because the boiler
has been subjected to too high temperatures.
*
the electrovalve ( 33 ) fails or the sieve is soiled
with scale.
– After the product has been repaired, it should
function properly and has to meet the safety
requirements as laid down and offi cially estab-
lished at this moment.