PARTS LIST + DISASSEMBLY ADVICE STAND
Pos
Description
Service Nummer
Stand rubber feet
Rubber feet above screw
Complete tray
Safety valve
Rubber ring in fi lling hole
21
22
23
24
25
9965 000 01692
9965 000 01702
9965 000 01703
9965 000 01704
9965 000 01782
Cover
Rubber feet boiler
Boiler complete
Locked insert
Bottom housing
26
27
28
29
30
9965 000 01783
4822 462 71999
9965 000 01784
9965 000 01788
9965 000 01789
Filter
Switch
Electro valve
Cordset Italian
plug
Cordset Europe
plug
31
32
33
34
9965 000 01790
9965 000 01791
4822 218 11561
9965 000 01792
9965 000 01793
GBR, FRA, DEU, NLD,
ESP, PRT, ITA
DFU
4222 001 92201
OPEN THE STAND
D
Below rubber feet
remove SCREW D (1 x)
E
E
E
remove SCREW E (3 x)
remove LOCKED INSERT 29
NOTE:
OPEN NOW THE STAND.
DON’T WORRY IF THE SNAPS AT THE SIDE WILL BE
BROKEN.
THEY ARE ONLY FOR THE ASSEMBLY.
THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.
ADJUSTMENT AND CONTROLS
– To avoid leakage of the sealings and damage to
the components in and on the boiler, NEVER clean
the boiler with vinegar, a descaling agent or other
chemicals.
– The boiler doesn’t contain serviceable parts.
Never disassemble the boiler body and /or compo-
nents on and in the boiler.
– ALWAYS REPLACE THE BOILER ( 28 ) WHEN:
*
the mechanical safety valve ( 24 ) has been acti-
vated.
*
the boiler thermostat or hand - resettable safety
thermostat are open, because the boiler has
been subjected to too high temperatures.
*
the electrovalve ( 33 ) fails or the sieve is soiled
with scale.
– After the product has been repaired, it should func-
tion properly and has to meet the safety require-
ments as laid down and offi cially established at this
moment.