PARTS LIST + DISASSEMBLY ADVICE STAND

Pos

Description

Service Nummer

Stand rubber feet
Rubber feet above screw
Complete tray
Safety valve
Rubber ring in fi lling hole

21
22
23
24
25

9965 000 01692
9965 000 01702
9965 000 01703
9965 000 01704
9965 000 01782

Cover
Rubber feet boiler
Boiler complete
Locked insert
Bottom housing

26
27
28
29
30

9965 000 01783
4822 462 71999
9965 000 01784
9965 000 01788
9965 000 01789

Filter
Switch
Electro valve
Cordset Italian 

plug

Cordset Europe 

plug

31
32
33
34

9965 000 01790
9965 000 01791
4822 218 11561
9965 000 01792
9965 000 01793

GBR, FRA, DEU, NLD,
ESP, PRT, ITA

DFU

4222 001 92201

OPEN THE  STAND

D

Below rubber feet
remove  SCREW D (1 x)

E

E

E

remove SCREW E (3 x)

remove LOCKED INSERT 29

NOTE:
OPEN NOW THE STAND.
DON’T WORRY IF THE SNAPS AT THE SIDE WILL BE 
BROKEN.
THEY ARE ONLY FOR THE ASSEMBLY.
THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.

ADJUSTMENT AND  CONTROLS

–  To avoid leakage of the sealings and damage to 

the components in and on the boiler, NEVER clean 
the boiler with vinegar, a descaling agent or other 
chemicals.

–  The boiler doesn’t contain serviceable parts.

Never disassemble the boiler body and /or compo-
nents on and in the boiler.

–  ALWAYS REPLACE THE BOILER ( 28 ) WHEN:

*

  the mechanical safety valve ( 24 ) has been acti-

vated.

*

  the boiler thermostat or hand - resettable safety 

thermostat are open, because the boiler has 
been subjected to too high temperatures.

*

  the electrovalve ( 33 ) fails or the sieve is soiled 

with scale.

–  After the product has been repaired, it should func-

tion properly and has to meet the safety require-
ments as laid down and offi cially established at this 
moment.

Summary of Contents for HI 910

Page 1: ...1 litre length steam hose 1 9 metre length cord set 1 9 metre maximum steam output 50 gr min Voltage 220 240Volt Frequency 50 60 Hz Power consumptium Boiler 1200 Watt Pressure 2 bar Iron 800 Watt 4322 277 00121 99 10 PCS 101 312 Product meets the requirements regarding interference suppression on radio and television After the product has been repaired it should function properly and has to meet t...

Page 2: ...PCS 101 313 EXPLODED VIEW IRON Screws d x 1 A 3 5 x 12 B 3 5 x 14 3x C M4 x 124 3x B B B C C A DAP0996 3 2 6 13 9 9 14 7 12 5 4 13 11 15 10 1 ...

Page 3: ...0 01681 9965 000 01682 Handle Rattle Skirt Soleplate Lamp 6 7 8 9 10 9965 000 01683 4822 492 71445 9965 000 01684 9965 000 01685 9965 000 01686 Ball swivel Back plate Thermostat Spring clamp Intermediate cable 11 12 13 14 15 9965 000 01687 9965 002 01689 9965 000 01690 4822 492 71001 9965 000 01691 Safety cut out TABLE UNIT IRON Steam switch Thermostat Thermostat Steam valve ...

Page 4: ... THERM DIAL 4 remove SCREW B 4x unlock HANDLE carefully SKIRT 8 remove ELECTRICAL WIRES remove EXTENSION PIECE 5 remove SPRING CLAMP FROM STEAM HOSE remove SCREW C 3x Bend back the contact points THERMOSTAT 13 ONLY cut CONDUCTOR A at location P remove SCREW D P Q B A D ASSEMBLY REQUIREMENTS THERMOSTAT 2 Instead of metal conductor A the new thermostat has a wire with AMP clamp After fixing screw D ...

Page 5: ...EXPLODED VIEW STAND PCS 101 315 E D DAP0998 22 23 21 24 26 27 25 28 30 27 29 31 33 32 34 ...

Page 6: ...ve LOCKED INSERT 29 NOTE OPEN NOWTHE STAND DON T WORRY IFTHE SNAPS ATTHE SIDE WILL BE BROKEN THEY ARE ONLY FORTHE ASSEMBLY THE STAND REMAINS CLOSE WITHOUTTHESE SNAPS ADJUSTMENT AND CONTROLS To avoid leakage of the sealings and damage to the components in and on the boiler NEVER clean the boiler with vinegar a descaling agent or other chemicals The boiler doesn t contain serviceable parts Never dis...

Reviews: