background image

HD9020

2-4

REPAIR INSTRUCTIONS

 

- To replace the Control Panel assy, remove the lid and 

remove the two screws holding the Control Panel  in place. 
Pull gently upwards to unhook the Control Panel , be aware 
that the Contol Panel is still connected by the flat cable. 
Unhook the flat cable from the PCB.  Please note, the flat 
cable connector will only fit in one way with respect to the 
receptacle.

Electrical diagram:

Resistance

Thermostat

Timer

Indicator

L

N

Upper
Heating
Element 

Lower
Heating
Element 

OPTIONAL (accessories)

 

- No specific issues

PARTS LIST

Pos

Service code

Description

1
2

3
4

5
6
7
8
9

10
11
12
13
14

15

16

4222 459 45778
4222 459 45779

9965 100 55821

4222 459 45780
4222 459 45781

4222 459 45787
4222 459 45788
4222 459 45882
4222 459 52311
4222 459 52251

4222 459 52241
4222 459 52321
4222 459 52261
4222 459 52271
4222 459 52281

4222 459 52291

9965 100 55822

4222 459 52301

Paddle

Bread pan 

suitable for appliances before week 1208

Bread pan 

suitable for appliances after week 1208

Control panel assy
Lid assy

Spoon
Measuring cup
Hook
5 pieces of crimp housing 2 wire connection
Main PCB

Power Supply PCB
12 pieces of Screw cover
Heating element, fuses, sensor assy
Sensor
Fuses

Motor assy 

suitable for appliances before week 1208

Motor assy 

suitable for appliances after week 1208

Base incl. power cord

= changed

Reviews: