background image

HD7854/84

Descaling

Regular descaling will prolong the life of your appliance and 
will guarantee optimal brewing results for a long time.
•  Follow the steps in the section headed “Preparing the 

appliance for use” see DFU (Direction for Use manual)

•  Instead of only water use a mix of water and Lemon sour.
•  For the best result leave the mix of water and Lemon sour 

for about 30 Minutes in the appliance, before you start with 
flushing the appliance.

•  To get the best results repeat above-mentioned step once or 

twice.

•  When finished, flush the appliance twice by repeating the 

above-mentioned steps only use water instead.

Volume adjustment

The PCB circuit board makes it possible to adjust the volume 
output by means of pushing the one-cup and two-cup user 
controls.
How to adjust the volume output:
1.  Be sure the boiler is fi lled properly, other wise perform fi ll 

procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Select the Coffee function 

 and select 

normal volume 

4.  Be sure a 

pod holder

 is placed, but 

without 

a Coffee 

POD. (Only adjusting with 

plain

 water)

5.  Place a cup on the drip tray cover and push the one-cup 

button.

6.  When the appliance has fi nished it is stabilized to perform 

the volume adjustment. 

7.  Empty the cup, podholder and push again for one cup 

setting, measure the volume output with a graduated 
beaker.  In the table you can fi nd the requirements for 
the minimum / maximum volume output cc/mL values 
depending from the country version:

One-cup setting, normal volume, 

Including Pod holder, 

water spec

. (Without Coffee pod)

Min. water cc/mL

Max. water cc/mL

Brazil version

81

101

France version

104

120

General version

125

141

8.  Unplug the appliance from the mains.
9.  Press the one and two cup button simultaneously and 

plug the mains on.

10. When above steps succeeded the main on/off switch- , 

one cup- and two cup button led will be on.

11. Depending if the volume has to de- or increase you have 

to push the one- or two cup button.
Every time you push the 1- or 2 cup button the LED will 
turn off for 0.5 second (feedback to user) and the pump 
time will be shortened or lengthened for 0.5 seconds 
depending which button was pushed.

Pushing 1 cup

 button pump, time will be 

shorten

 with 

0.5 sec is approximately − 3.5 cc/mL  (less coffee)

Pushing 2 cup

 button pump, time will be 

lengthen

 with 

0.5 sec is approxi 3.5 cc/mL  (more coffee)
When the volume has to increase with 10 cc for example, 
push the 

2 cup

 button 3 times.

The new value will only be stored when you switch the 
appliance off by 

pushing

 the main switch.

(LED will turn off )

12. Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 7 – 11.

13. End.

REPAIR INSTRUCTION

4-11

Summary of Contents for HD7854/84

Page 1: ...iler 1450 W Steam heater 1200 W 12 02 Standby power switched off 1 W Standby power 30 W switched on 30 min room temperature Pressure Coffee system 1 6 Bar Pressure Steam system 1 Bar Contents water reservoir 1200 cc mL Contents milk reservoir 120 cc mL Auto shut off 30 min Variable Coffee volume Min Normal and Max see Table Colour setting True red Coffee volume overview Min cc mL Normal cc mL Max ...

Page 2: ...ee way valve with Check valve Brew Chamber g h e d f aa j c b o kk i a Legend Low pressure tube High pressure tube Low pressure connections High pressure connections a p aa ll CONTROL PCB USER INTERFACE PCB CONNECTION PCB L N Boiler Pump M Steam pump M Fuse Push buttons Temp sensor boiler Water level sensor Descale tool detector Milk tank detection sensor Fuse Thermo block Fuse Fuse Temp sensor Th...

Page 3: ...detail Gently pull out the switch assembly Reassemble follow above steps backwards DISASSEMBLY AND RE ASSEMBLY ADVISE Remove brew chamber cover to reach user interface PCB To remove the brew chamber lid cover place the screwdriver on the positions see picture and lift the cover over the snap locks on both positions The cover lid can now be lifted a little Remove the complete cover by unlocking the...

Page 4: ...podholder and push again for one cup setting measure the volume output with a graduated beaker In the table you can find the requirements for the minimum maximum volume output cc mL values depending from the country version One cup setting normal volume Including Pod holder water spec Without Coffee pod Min water cc mL Max water cc mL Brazil version 81 101 France version 104 120 General version 12...

Page 5: ... by reconnect the power cord a second time to the net and check if the main switch LED will blink very rapidly for approximately 1 second When the consumer pushes the one or two cup button the Senseo will start automatically the pump to fill the boiler and after that the Steam heater will also be filled When the boiler is filled the pump stops pumping Pump time approximately 22 seconds When the fi...

Page 6: ...4222 259 49341 4222 259 41801 Padholder assy 1 cup Padholder assy 2 cup Milk Tube Milk container assy IH Driptray cover Driptray assy Water container assy Decalcification dummy IH Lasered printed lid panel Lever Push rod Slider spring User interface PCB assy Brew chamber seal Ejector pin Distribution disk Collector Spout housing cover Spout lever Spout Sensor decalcification assy Steam connecting ...

Page 7: ...HD7854 84 EXPLODED VIEW 2 1 7 6 5 3 4 8 7 11 ...

Page 8: ...HD7854 84 EXPLODED VIEW g h Z 11 10 12 9 13 14 15 16 8 11 ...

Page 9: ...HD7854 84 EXPLODED VIEW gg c i a b i j ll ff g p f e aa U T V S X 18 46 22 20 21 23 19 17 30 31 34 25 24 27 26 28 29 35 33 32 33 9 11 ...

Page 10: ...HD7854 84 EXPLODED VIEW c d e Z Y X W W V U T S 37 36 38 39 40 28 47 48 y 41 50 49 51 53 10 11 ...

Page 11: ...HD7854 84 EXPLODED VIEW bb cc dd k p l m n ee o gg ll hh kk jj ii aa ff 45 44 42 42 43 11 11 ...

Reviews: