background image

HD7853/60 /61 /62

6-11

PARTS LIST

Pos

Service code

Description

Remark

1
2
3
4
5

4222 259 44210
4222 259 44220
4222 247 07261
4222 259 50422
4222 247 06991

Padholder assy 1-cup 
Padholder assy 2-cup
Riser Pipe
Milk container assy 
Drip tray cover sheet

Deep Black
Deep Black

Aqua Fresh
Dark Grey

6
7
8
9

10

4222 240 00711
4222 247 65781
4222 259 49221
4222 259 50442
4222 247 58300

Driptray cover
Driptray
Decalcifi  cation dummy assy
Water container assy 
Lever

Deep Black

Translucent dark grey
Dark Grey

11
12
13
14
15

4222 247 58270
4222 240 01410
4222 247 06810
4222 240 05990
4222 247 41920

Push rod
Slider spring
Brew chamber seal
Ejector pin
Distribution disk

16
17
18
19
20

4222 247 58910
4222 259 50401
4222 247 65161
4222 247 66011
4222 247 60570

Collector
Brew chamber assy 
Spout housing cover 
Spout lever
Spout

Deep Black
Deep Black
Deep Black

21
22
23
24
25

4222 259 50902
4222 259 42440
4222 259 49363
4222 259 50892
4213 247 05250

Sensor decalcifi cation assy
Steam connecting assy
Spouthousing 
Sensor milk container
Foot

Deep Black

26
27
28
29
30

4222 259 42430
4222 259 41230
4222 247 58780
4222 259 50831
4222 259 41502

Lid switch lid close detection assy
Steam pump 
Valve outlet
3-Way Valve  assy
Backcover assy

CEME E151
Deep Black

Deep Black

31
32
33
34
35

4222 247 05510
4222 259 41870
4222 259 37240
4222 259 41750
4222 247 57194

Corrugated tube
Fuse assy welded (2 pieces)
Pump 
Thermo block assy
Housing

ULKA HF 230 V ~50 Hz

Deep Black

36
37
38
39
40

4222 247 66472
4222 247 66462
4222 247 66453
4222 247 65703
4222 247 61940

On/Off button
2-cup button
1-cup button
Front Cover
TCO cap

Dark Grey
Dark Grey
Dark Grey
Deep Black

41
42
43
44
45

4222 259 35440
4222 247 05130
4222 259 41620
4222 259 50283
4222 259 50292

Boiler assy 
NTC O-ring
NTC boiler assy
Base PCB assy main
Interconnect PCB assy + Water level sensor

V7.0 - 230 V

120 - 240 V

46
47
48
49

4222 247 60260
4222 259 42160
4222 259 41180
4222 259 42680

T-piece
Venting valve assy
Safety valve assy
One way valve

Summary of Contents for HD7853/60

Page 1: ... as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240V Frequency 50 60 Hz Power consumption 2650 W Boiler 1450 W Steam heater 1200 W Standby power switched off 1 W Standby power 30 W switched on 30 min room temperature Pressure Coffee system 1 6Bar Pressure Steam system 1 Bar Contents water reservoir 1200 cc mL Contents milk reservoir 120 cc mL Auto shut off 30 min Colour s...

Page 2: ...e Brew Chamber g h e d f aa j c b o kk i a Legend Low pressure tube High pressure tube Low pressure connections High pressure connections a p aa ll CONTROL PCB CONNECTION PCB L N Boiler Pump M Steam pump M Fuse Push buttons Temp sensor boiler Water level sensor Descale tool detector Milk tank detection sensor Fuse Thermo block Fuse Fuse Temp sensor Thermo block Lid close detection switch TCO Y W X...

Page 3: ...ap lock which is holding the micro switch assembly see picture for detail Gently pull out the switch assembly Reassemble follow above steps backwards Remove brew chamber cover to reach user interface PCB To remove the brew chamber lid cover place the screwdriver on the positions see picture and lift the cover over the snap locks on both positions The cover lid can now be lifted a little Remove the...

Page 4: ...ppliance on and wait until the unit is ready to brew 3 Choose the setting of which you want to adjust the volume 4 Be sure a pod holder is placed but without a Coffee POD Only adjusting with plain water 5 Place a cup on the drip tray cover Press the 1 cup button once to measure the black coffee volume press the 1 cup button twice to measure the coffee volume in a cappuccino 6 When the appliance ha...

Page 5: ...sful the software will clear a Boiler_empty_flag in the Eeprom By means of this Boiler_empty_flag the system knows the boiler is filled or not When the Senseo is switched off or disconnected from the mains the value of the Boiler_empty_flag is stored in the Eeprom chip Restoring the Boiler_empty_flag to production default Some times it is needed that the boiler of the Senseo have to be emptied Thi...

Page 6: ... 42440 4222 259 49363 4222 259 50892 4213 247 05250 Sensor decalcification assy Steam connecting assy Spouthousing Sensor milk container Foot Deep Black 26 27 28 29 30 4222 259 42430 4222 259 41230 4222 247 58780 4222 259 50831 4222 259 41502 Lid switch lid close detection assy Steam pump Valve outlet 3 WayValve assy Backcover assy CEME E151 Deep Black Deep Black 31 32 33 34 35 4222 247 05510 4222...

Page 7: ...HD7853 60 61 62 7 11 2 5 6 7 3 1 9 8 4 EXPLODEDVIEW ...

Page 8: ...HD7853 60 61 62 8 11 g h 11 10 12 13 14 15 EXPLODEDVIEW ...

Page 9: ...HD7853 60 61 62 9 11 gg c i a b i j ll ff g p f e aa U T V S X 18 17 22 20 21 23 19 16 29 30 33 25 24 27 26 45 28 34 32 31 32 EXPLODEDVIEW ...

Page 10: ...HD7853 60 61 62 10 11 c d e Y X W W V U T S 41 40 42 43 44 45 y 39 35 38 37 36 EXPLODEDVIEW ...

Page 11: ...HD7853 60 61 62 11 11 bb cc dd k p l m n ee o gg ll hh kk jj ii aa ff 49 48 46 46 47 EXPLODEDVIEW ...