HD7817/20 /21 /22
4-7
Restoring the Boiler_empty_fl ag to production default:
Some times it is needed that the boiler of the Senseo have
to be emptied.
This for instance in wintertime were the possibility exists
that the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the
Boiler_
empty_fl ag
again to production default.
Bringing the Senseo back into production status, has the
benefi t the fl ush routine will be activated automatically
when installed by the consumer, see topic
Automatic fi lling
procedure
.
To
SET
the
Boiler_empty_fl ag
can be done by:
Keep the 1-cup button pressed while plugging in the
power cord of the appliance.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and
push the main switch.
The main switch LED should light continuously.
Repair instruction