background image

HD6553/10

3-10

Disassembly- and Reassembly advice

Disassembly information

To remove the brew chamber lid cover handle as follows: 

 

Place the screwdriver on the

positions (see picture 1) and 

lift the cover over the snap 

locks on both positions.

 

The cover lid can now be

lifted up a little and to 

remove the complete cover 

including lever and push rod 

squeeze strongly with two 

fingers both legs of the push 

rod (see picture 2) to each 

other, so that the two pins 

will get out of the hinge 

position on the brew 

chamber.

 

To remove lever from lid cover, take a screwdriver and 

bend carefully the two lips/ribs in the lid cover outwards 

and push the lever with force out of the hinge.

 

Reassemble follow steps backwards, without using a 

screwdriver.

To remove the back cover handle as follows:

 

Remove valve outlet.

 

Start at the upper side of the back cover and stick a 

screwdriver into the 2 snap locks positions and gently 

pull the back cover from the appliance so that a little 

chink between back cover and brew chamber becomes 

visible.

 

Put the screwdriver in to the 4 rectangular holes (snap 

locks) at the back and gently pull the screwdriver such 

away that the lips of the snap locks are bent outwards.

 

If all clicks positions are loose, it is possible to remove 

the back cover.

 

Reassemble follow steps backwards.

picture 1

picture 2

Removing Brew chamber head handle as follows:

 

Disassemble back cover!

 

Place the appliance such a way that you are looking at 

the boiler.

 

First remove the boiler from the snap lock position of the 

brew chamber.

 

To remove the brew chamber, 

use your both thumbs (see 

picture 3) and push strongly 

with a little distortion 

(rotation) until the brew 

chamber comes loose.

 

Reassemble follow above steps backwards.

To reach the components placed on the base handle as 

follows:

 

First remove back cover, brew chamber and 3-way valve.

 

Remove both Torx T15 screws see exploded view in the 

near of position 

A

.

 

Bend the 2 click snap locks with a screwdriver (see base), 

and the housing can now be removed.

 

To remove the rest of the housing unlock the last 4 snap 

locks at the base and gently pull of the front cover.

 

To reassemble follow above steps backwards.

picture 3

Summary of Contents for HD6553/10

Page 1: ...ur setting Star white Functions º Coffee boost technology º Crema improvement º Strength select only for HD6554 HD6555 HD6556 Materials º Housing PP º Housing ABS only for HD6556 º Water container PP º Brew chamber PA º Spout POM º Hoses Silicon º Drip tray Driptray cover PP º Drip tray cover Stainless steel only for some HD6556 º Lever PC º Lever Chrome painted ABS only for some HD6556 Consumer R...

Page 2: ...sh version 100 ml 69 C 73 C Water specification in mL without coffee pod 1 cup ml with 1 cup pod holder 2 cup ml with 1 cup pod holder General version normal cup 122 ml 133 10 266 10 French Spanish version normal cup 100 ml 109 20 218 20 All countries short cup 60 ml 71 10 142 10 Difference between left right volume 10ml 10ml Functional diagram Boiler Pump 3 way valve Brew head Water Container Ele...

Page 3: ... back cover and brew chamber becomes visible Put the screwdriver in to the 4 rectangular holes snap locks at the back and gently pull the screwdriver such away that the lips of the snap locks are bent outwards If all clicks positions are loose it is possible to remove the back cover Reassemble follow steps backwards picture 1 picture 2 Removing Brew chamber head handle as follows Disassemble back ...

Page 4: ...ting the right PCBA modus Enable Disable the Intensity select feature The PCBA is standard delivered with the Intensity select feature disabled this for easy servicing the existing SENSEO Original HD78xx HD6553 range with OPR Boiler installed The Intensity select function can be simple enabled disabled 1 Hold the 2 cups button while applying power to the appliance 2 Release the 2 cups button 3 Pre...

Page 5: ...sh the one cup button 5 When the appliance has finished you are able to perform the volume adjustment Adjusting the normal 1 cup volume WEU or French Spain 6 Empty the cup podholder and push again for one cup setting measure the volume output with a graduated beaker In the table above you can find the requirements for the minimum maximum water volume output cc ml values 7 Unplug the appliance from...

Page 6: ... volume is not within specification repeat steps 13 17 18 End Example table switching from WEU to French Spain specification or vice versa you need to execute below Change volume setting Adjusting normal smooth 1 cup volume step 6 12 Adjusting short strong 1 cup volume step 13 17 WEU French Spain Push 7x 1 cups with water in tank 16x 2cups without tank French Spain WEU Push 7x 2 cups with water in...

Page 7: ...y valve 18 4222 259 65481 Boiler assy OPR 230 V 19 4222 247 75271 TCO cap for OPR boiler 20 4222 247 43690 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 23 4222 259 68451 PCB assy OPR Intensity select 230 V 24 4222 259 68401 Button frame printed Black 26 4222 259 63422 On off button printed 27 4222 247 72932 Base plate Black 28 4222 247 05130 O ring NTC 29 422...

Page 8: ...HD6553 10 8 10 A 15 12 10 14 13 11 16 6 2 1 4 3 7 8 5 9 Exploded view ...

Page 9: ...HD6553 10 9 10 36 35 34 31 32 17 18 22 24 23 19 20 30 21 26 27 29 28 33 A Exploded view ...

Page 10: ...HD6553 10 10 10 Version history 17 07 Version 1 1 HD6553 10 initial release ...