background image

GC4620

REPAIR INSTRUCTIONS

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 25

, it must be replaced. 

Continued usage is not allowed.

- If 

COVER 12

 is provided without type plate information eg. type number, voltage etc. When replacing the cover, engrave the 

type number & voltage on the type plate with a sharp object.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 
minutes. The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working 
properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

3-5

Summary of Contents for GC4620

Page 1: ...ion on radio TV After the product has been repaired it should function properly has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power 2000 2400 W Dimension F box 13 5 cm x 33 5 cm x 16 8 cm Product weight 1 72 kg SteamGlide Soleplate This specially treated soleplate is designed with 2 distinctly different types o...

Page 2: ...ews E1 E2 E3 F3 Disassemble WATER TANK HOUSING COVER TRIM ASSY 6 Disengage Quick connectors of CORDSET 25 Disassemble CORDSET 25 DISASSEMBLY ADVICE HOUSING 11 COVERTRIM 5 SPRAY PUMP ASSY 7 SOS PUMP ASSY 8 THERMOSTAT DIAL 27 THERMOSTAT BUSH 26 HEAT SHIELD 13 COVER BOTTOM 12 RYTON SPACER 3 DOSING SEAL 4 SOS SEAL 2 SOLEPLATE ASSY 1 Remove Screws D1 D2 D3 Disassemble HOUSING 11 Disassemble SPRAY PUMP ...

Page 3: ...te after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton...

Page 4: ...39 026 29450 4239 010 11000 4239 026 29720 4239 026 29790 4239 026 28490 4239 021 43860 4239 021 44960 4239 021 44310 4239 026 29600 4239 026 29630 4239 026 28400 4239 000 09950 4239 026 28140 4239 021 44820 4239 026 05990 Soleplate assy SOS seal Ryton spacer Dosing seal Cover trim Water Tank Housing Cover Trim Assy Spray pump assy SOS Pump assy Tank top seal Plastic rattle spring Housing Non Ioni...

Page 5: ...GC4620 EXPLODEDVIEW MAX C2 A C1 D1 D3 E3 E2 E1 F3 G3 G2 G1 F2 F1 B D2 16 28 22 17 8 13 11 5 12 1 6 9 Inlay cap 24 14 7 4 2 27 25 21 18 10 15 23 26 3 Cord clamp 5 5 ...

Reviews: