GC3640

PARTS LIST & ELECTRICAL DIAGRAM

RESISTOR

LAMP

FUSE

N

L

E

HEATING
UNIT

INPUT

THERMOSTAT

4-5

Pos

Service code

Description

1
2
3
4
5

6
7
8
9

10
11

17
18

19
20
21
22

24
25
26
27

4239 021 39870
4239 015 54410
4239 025 98250
4239 015 55920
4239 021 53140

4239 010 11290
4239 026 36980
4239 026 37230
4239 000 07760
4239 000 09802

4239 026 13220
4239 021 53590
4239 021 57931
4239 015 55800
4239 021 54550

4239 021 54701
4239 026 36850
4239 026 34920
4239 026 34930

4239 021 54921

4239 021 53160
4239 026 36890
4239 026 36930
4239 026 10270

Soleplate mounted assy  230 V / 2200 W
SOS seal
Ryton spacer
Dosing seal
Cover assy

Heat shield
Swivel moulded
Backplate moulded
Cord set  EU
Cord set  Singapore / Hong Kong

Thermostat bush
Water tank & housing assy
Water tank & housing assy - Singapore
Tank top seal
Thermostat dial printed

Thermostat dial printed - Eng text
Inlay moulded
Spray knob moulded
SOS knob molulded

Sub-inlay printed  &  Steam slider assy

Filling door assy
Backplate screw cover
Inlay cover moulded
Filling cup

= changed

Summary of Contents for GC3640

Page 1: ...ght 1 59 kg Water advice In case you live in an area with hard water e g water hardness more than 8 dGH it is recommended to use a mixture of 50 tap water and 50 demineralised water Automatic energy saving 90 of the energy a steam iron uses is used to convert water into steam This steam iron with innovative mechanism in the handle makes sure that you still get high steam performance but with optim...

Page 2: ...4 SUB INLAY PRINTED 22 WATER TANK HOUSING ASSY 11 SWIVEL MOULDED 7 CORDSET 9 Disassemble FILLING DOOR ASSY 24 Remove screw C Disassemble SUB INLAY PRINTED 22 Disassemble TANK TOP SEAL 17 Remove screw D1 D2 D3 Disassemble WATER TANK HOUSING ASSY 11 Disengage quick connectors of CORDSET 9 Remove screw E1 E2 Disassemble swivel column Disassemble SWIVEL MOULDED 7 Disassemble CORDSET 9 COVER ASSY 5 SOL...

Page 3: ... of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 21...

Page 4: ... 021 54701 4239 026 36850 4239 026 34920 4239 026 34930 4239 021 54921 4239 021 53160 4239 026 36890 4239 026 36930 4239 026 10270 Soleplate mounted assy 230 V 2200 W SOS seal Ryton spacer Dosing seal Cover assy Heat shield Swivel moulded Backplate moulded Cord set EU Cord set Singapore Hong Kong Thermostat bush Water tank housing assy Water tank housing assy Singapore Tank top seal Thermostat dia...

Page 5: ...GC3640 EXPLODED VIEW MAX C D1 D2 D3 F3 F2 F1 A E1 B1 E2 B2 24 17 11 8 26 19 20 21 22 6 27 5 4 3 7 9 Swivel column 25 18 2 1 10 5 5 ...