Page 1: ...AutoDome Instruction Book EnviroDome Indoor Pendant In ceiling Model ...

Page 2: ...A No 70 1981 provides information with respect to proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors loca tion of discharge unit connection to grounding elec trodes and requirements for the grounding electrode FCC ICES INFORMATION U S A AND CANADIAN MODELS ONLY WARNING This equipment has been tested and found to comply with...

Page 3: ...rancher une prise de terre sur les bornes d alimentation 24 Volts ou aux bornes d alimentation de l appareil Les cordons secteur 220 240 V 50 Hz Les cordons secteur 220 240 V 50 Hz entrée et sortie doivent êtro conformes aux versions les plus récentes de la publication 227 de la C I E ou à la publication 245 de la C I E SICHERHEITSVORKEHRUNGEN Aus Platzgründen kann diese Warnung auf der Unterseite...

Page 4: ...nalmente requieren que el interruptor esté posicionado en ON El cable de ali mentación es el medio principal de desconexión del equipo FUENTES DEALIMENTACIÓN EXTERNAS Unidades de 24VCA No exceder 30 VCA de entrada Voltage suplido a la unidad no debe exceder 30 VCA Voltage de entrada normal es de 24 VCA El cableado de 24 VCA provisto por el usuario debe cumplir con las normas eléctricas Clase 2 de ...

Page 5: ...ome Instruction Book EnviroDome and Indoor Pendant Installation Instructions 5 In ceiling AutoDome Installation Instructions 21 FastAddress 31 AutoDome Security 33 Troubleshooting Guide 34 AutoDome Locked Commands 35 AutoDome User Manual Insert AutoDome Instruction Book EnviroDome Indoor Pendant In ceiling Model ...

Page 6: ...e STEP A2 Place the upper half of the G3 AutoDome into the star shaped foam and remove all packing material Make sure to remove all debris that may interfere with the camera If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper If any items are missing notify your Philips Communication Security Imaging Sales Representative or Customer Service ...

Page 7: ...6 ...

Page 8: ...ided STEP A3 7 Remove the camera s plastic lens cover If installing the EnviroDome model a desiccant bag and holder are included to reduce expo sure to moisture Ensure that the desiccant bag is securely tucked into the ring of the lower housing as shown in the photo inset at right Align the ball studs in the lower half with the clips in the connector end of the upper half The safety cable should p...

Page 9: ...8 ...

Page 10: ...le side is down STEP A6 Remove the 4 top screws as shown and lift the top plate carefully off the dome The cable is approximately 5 cm 2 in long so remove carefully from the PCB Remove the top plate cable if necessary from the dome to access the address switch Set the address switch as in Step A7 and make a note of it 9 Installation Guide Pendant EnviroDome ...

Page 11: ...10 ...

Page 12: ...ved the baud rate can be changed with the dip switch Switch 1 RS 232 Baud rate Off 9600 On 19 2K STEP A8 Reconnect the top plate cable Replace the top plate and gasket Align the yellow dot on the connector top with the dimple on the housing and firmly tighten the four screws Do not overtighten 11 Installation Guide Pendant EnviroDome ...

Page 13: ...ADDRESS SWITCH BAUD RATE DIP SWITCH RS232 ONLY SWITCH 1 RS 232 Baud rate Off 9600 On 19 2K 12 ...

Page 14: ...n should be performed by qualified service per sonnel only in accordance with the National Electrical Code or applicable local codes Refer to applicable instal lation section The G3 AutoDome can be mounted to a wall mast pole roof pipe or a corner mount You must have installed the appropriate mount before installing the AutoDome Each mount includes its own mounting instructions Installation Guide ...

Page 15: ...ware not supplied for installation The mounting surface and unit s weight should be carefully considered The following instructions reference a 120 230 VAC Pendant wall plate installation mounted to an existing structure The instructions assume the safety cable power video and control cables have already been properly installed Refer to mounting instructions ...

Page 16: ...d pin 9 C NOTE Daisy chain configuration is not possible if fiber optic accessory is used Attach the installation assist cable to the eye hook on the top of the dome and close the safety cable For pipe mounting user must provide a cable See mounting guide for instructions 15 C Biphase Ground Biphase Biphase RS 232 Ground RS 232 TX RS 232 RX 24VAC Neutral Pendant Not Connected EnviroDome 24VAC Heat...

Page 17: ...16 ...

Page 18: ...VX2460X Kits User must supply a Philips LTC 5401 transformer 24VAC 50VA or equivalent Check for the following 1 LINEVOLTAGE into transformer is between 105 to 132VAC for 120VAC systems or 195 to 253VAC for 230VAC systems 2 Transformer can supply between 21 and 32 VAC to the EnviroDome under load 3 24 VAC wiring is adequate for powering The following are recommended wire run lengths at 68 F 20 C Fo...

Page 19: ...r Input Connector from Control System 1 24VAC 2 24VAC 3 Heater 4 RS 232 Ground 5 RS 232 TXD 6 RS 232 RXD 7 Biphase Ground 8 Biphase 9 Biphase 120VAC 105 to 132 230VAC 195 to 253 RS 232 Ground RS 232 TXD RS 232 RXD Biphase Ground Biphase Biphase Top of EnviroDome LTC 5401 Power Supply MainsVoltage Input ...

Page 20: ...OTE Newer models use a slotted screw instead of an Allen screw You may now power the G3 AutoDome STEP A14 STEP A15 If you are using the FastAddress feature go to Page 31 for additional information Congratulations You ve installed the G3 AutoDome 19 Installation Guide Pendant EnviroDome ...

Page 21: ...20 ...

Page 22: ...ior to 2 00 use the following settings Switch 1 ON RS 232 Baud rate 9600 Switch 2 OFF RS 232 Baud rate 19 2 K Carefully remove the G3 AutoDome from the box Save all packing material as it can be used for setting up the camera and for transporting the dome If the item appears to have been damaged in ship ment replace it properly in its carton and notify the shipper If any items are missing notify y...

Page 23: ...BAUD RATE DIP SWITCH ADDRESS SWITCH 22 ...

Page 24: ... lower portion and align the camera dome yellow markers Attach the dome window to the camera module by aligning the blue Lock labels Snap the dome cover into position by pressing gently on the dome 90 from the blue labels 23 Installation Guide In ceiling AutoDome ...

Page 25: ...24 BLUE LABEL 90 90 YELLOW MARKERS ...

Page 26: ...ing sure that the unit is vertical With the red dot on the camera module facing the red dot on the backbox slide the camera module into the backbox module using the guides Note that the camera is shown turned 180 degrees to illus trate red markers 25 Installation Guide In ceiling AutoDome ...

Page 27: ...26 RED MARKERS RED DOTS FACING EACH OTHER ...

Page 28: ...amper clip into the locking ring just to the right of either blue label A straight blade screwdriver will help push the clip in place While pressing up twist the dome window locking ring clockwise approximately 1 4 turn Verify that the arrowheads on the green labels have mated The camera will initialize 10 seconds after it is properly installed 27 Installation Guide In ceiling AutoDome ...

Page 29: ...28 GREEN LABELS TURN TO LOCK ...

Page 30: ...ot remove camera from pan tilt Remove the entire receiver driver pan tilt and camera assembly from the AutoDome system to prevent damage to the flexible cable and connector To install the trim ring align the yellow dots on the inside of the trim ring with the yellow dots on the locking ring To ensure proper installation push on the trim ring vertically until a click is felt Installation is now com...

Page 31: ...power off the unit and remove the dome so that it is away from the camera While using proper eye protection clean the dome by using clean compressed air from a spray can and microwave safe paper towels and reseat the dome In instances of high humidity the EnviroDome model may require a replacement desiccant bag To order contact Philips CSI and specify part number 303 3804 003 ...

Page 32: ...camera number at the keyboard that dome will also respond to the command 2 All domes respond to the On 998 Enter com mand regardless of their FastAddress status NOTE In systems with multiple monitors other domes may also enter the FastAddress mode As commands which are unique for each dome are entered the other domes automatically exit the FastAdress mode and only the target dome remains active Fo...

Page 33: ...he end of the FastAdress mode press Off 1 Enter to clear the address c There will be a visual confirmation that the address was cleared Use the On 997 Enter command to check confirm camera addresses For example if referring to Camera 3 press Camera 3 Enter then On 997 Enter This will cause all cameras to briefly display their addresses FastAddress is stored to nonvolatile memory and will not chang...

Page 34: ...and are selected using the joystick The 0000 password four zeros is the AutoDome s default password and allows Off 90 Enter to directly unlock the Advanced Menu com mands If the 9999 password is used the AutoDome is totally unlocked so that all AutoDome commands can be executed no Off 90 Enter is required to use Advanced Commands If any other 4 digit password is set the AutoDome will prompt for th...

Page 35: ...not correct 1 Try resetting factory defaults On 40 Enter 2 Position camera so the entire view is white piece of paper or white wall 3 Turn on white balance Off 30 Enter Move joystick until one push W G is selected Wait 10 seconds Press the Iris button to return 4 If this does not work restore factory defaults Set 899 Enter Note that this will erase all presets and settings 5 Once you have restored...

Page 36: ...1 Enter Sets the current position as the left limit of Auto Pan Default is 0 degrees Right Limit Set 102 Enter Sets the current position as the right limit of Auto Pan Default is 359 9 degrees Inactivity On Off 9 Enter Selects the mode that the dome will revert to after a duration without operator activity Default is OFF Preset On Off 15 Enter Increase Decrease On Off Tour Period the time between ...

Page 37: ...tivating Gain Control Electronically brightens darker scenes which may cause graininess in low light scenes The factory default setting is AUTO Choices Fixed Select Fixed then program under next menu option Off Camera uses only the IRIS to adjust to low light Auto Camera will add electronic gain must be set for auto night mode in Day Night models Fixed Gain Level Adjusts the fixed gain level The f...

Page 38: ...of the Lens Setup menu hierarchy Auto Focus G3 AutoDome automatically focuses on the subject in the center of the screen The factory default setting is SPOT Choices Constant Auto Focus is always active even while moving Manual Auto Focus is inactive manual focus must be used Spot Auto Focus activates after the camera stops movement once focused Auto Focus is inactive until camera is moved again Au...

Page 39: ...fied in the Inactivity Period next menu option without operator activity Choices Off remains on current scene indefinitely Scene 1 returns to preset 1 Prev Aux returns to previous activity previous activities include Aux commands 1 2 8 50 52 Inactivity Period The time period of inactivity before the above action will occur Choices Sliding Scale from 3 seconds to 10 minutes AutoPivot AutoPivot auto...

Page 40: ...ault 0 120 NIGHT MODE NIGHT MODE THRESHOLD NIGHT MODE COLOR On Off Auto Sliding Scale 0 20 On Off Factory Default 1 60 1 4 NTSC 1 50 1 3 PAL Auto SLOW SHUTTER Day Night Settings For Day Night Models Only ADVANCED MENU Continued LENS SETUP AUTO FOCUS AUTO IRIS IRIS SPEED MAX ZOOM SPEED DIGITAL ZOOM FOCUS SPEED Constant Manual Sliding Scale 1 normal 10 fast default 2 On Off Factory Default Constant ...

Page 41: ... Sliding Scale 3 sec 10 min PTZ FIXED SPEED Sliding Scale 1 sec 60 sec default 30 sec Sliding Scale 1 slow 15 fast default 4 Off Scene 1 Prev Aux Figure AM3 PTZ Setup DISPLAY SETUP DISPLAY ADJUST ON SCREEN DISPLAY LANGUAGE ZONE MASKING On Off Factory Default Available Zones from 1 to 16 English Spanish French German Figure AM4 Display Setup ...

Page 42: ...NOTES 41 ...

Page 43: ...NOTES 42 ...

Page 44: ...moved restored Preset Tour On Off from the Preset tour Example Set 915 Enter will clear Preset 15 from the tour Presets can still be displayed manually PTZ RECORD PRESET Commands Keystrokes Description Record A On Off 100 Enter Records A camera and PTZ controls that can be played back Once the sequence is record ed you must exit record in order to play back Record B On Off 101 Enter Records B came...

Page 45: ...NOTE Remove this user manual and supply to user AutoDome Instruction Book EnviroDome Indoor Pendant In ceiling Model ...

Page 46: ...ts you name that Preset using the joystick focus and iris buttons see Fig 2 The name can be up to 16 charac ters long This Preset can later be viewed with the Shot Enter command where is 1 99 Preset Tour Once you have stored Presets you can make the AutoDome cycle through all the Presets or selected Presets This is called a Preset tour To include or remove presets on a tour type Set 900 Enter This...

Page 47: ...B is available by using the On Off 101 Enter command Playback can be continuous On 50 Enter forA On 52 Enter for B or one shot On 51 Enter forA On 53 Enter for B Changing the Auto Pan and Auto Scan speeds The Auto Pan and Auto Scan speeds Fig 6 can be adjusted using the On 14 Enter command Use the joystick to adjust the speed It is helpful for the Pan or Scan to be active when you enter the adjust...

Page 48: ...1 37 2001 Philips Electronics N V Printed In U S A 2001 Philips Communication Security Imaging Inc All Rights Reserved Philips is a registered trademark of Philips Electronics N V Data subject to change without notice ...