HX6160, HX6921, HX6942, HX6950, HX6972,
HX6992, HX6993
4235-057-56101 _ 12-08-15
(YY_MM_DD)
3-7
REPAIR INSTRUCTION
-
Brush head (pos 2) In case of a defective brush head, the complete
brush head must be replaced.
-
Charging unit (pos 1) In case of a defective charging unit or
cordset, the complete charging unit must be replaced.
-
Handle toothbrush (not available in service channel) The batteries
inside cannot be replaced. In case of a defect, the complete unit
must be replaced.
-
Charging the handle. The handle should be charged for at least 24
hours during the first few days of use.
-
Sanitizer(pos 3) In case of a defective sanitizer, the complete
sanitizer unit must be replaced.
-
Sanitizer UV light bulb Replacement(pos 4)
Environment
- The rechargeable battery inside your Sonicare cannot be replaced,
but is easy to remove for recycling. Refer to the instructions below
for battery removal.
- Do not throw away the appliance or the UV light bulb(bulb
contains mercury) with the normal household waste at the end of
it’s life, but hand it in at an official collection point for proper
disposal.
- If you have any recycling questions, contact your local waste
management office.
5. The rechargeable battery can now be recycled and the rest
of the product discarded appropriately.
1.
To deplete the rechargeable battery of any charge,
remove the handle from the charger, turn on the Sonicare
and let it run until it stops. Repeat this step until you can
no longer switch on the Sonicare.
3.
Hold the handle upside down
and push down on the shaft
to release the internal
components of the handle.
2.
Insert a screwdriver into the
slot located at the bottom of
the handle and turn
counterclockwise to release
the bottom cap.
4.
Insert the screwdriver under
the circuit board, next to the
battery connections, and
twist to break the
connections. Remove the
circuit board and pry the
battery from the plastic
carrier.