2-3
2-3
Service position A
Service position C
Repair Hints
1) Remove 3 screws L (see Figure 11 and Figure 12) to
loosen the Amplifier Board (pos 1102).
2) Remove 2 screws M (see Figure 12) to loosen the
Interconnect Board (pos 1103).
Service position B
DISMANTLING INSTRUCTIONS (POWER BOX)
Dismantling of the Amplifier Board and Supply Board and Interconnect Board
3) Remove 3 screws N (see Figure 11 and Figure 12) to
loosen the Supply Board (pos 1101).
DISMANTLING INSTRUCTIONS (POWER BOX)
Figure 11
Figure 12
1) WARNING
Switching Mode Power Supply (SMPS) Board consists of high voltage filter capacitors (2203 or 2210).
Safety measures must be taken by the repair technician during servicing:
-
When the supply is on, avoid touching the SMPS Board and the high voltage filter capacitors (2203 or 2210).
-
When the supply is off, make sure to discharge the high voltage filter capacitors (2203 or 2210) with a suitable value resistor
before any servicing to prevent electric shock.
2) The flex cables are very fragile, care should be taken not to damage them during repair. After repair, be very sure that the
flex cables are inserted properly into the flex sockets before encasing, otherwise faults may occurs.
Use a insulation sheet to
prevent any damaged or
short-circuit of the boards.
Capacitors
2203 or 2210
Summary of Contents for EMOTIVE Micro MZ-1000