13
Design-in Guide - EasyAir SNS300
April 2019
5°
~ 7° Angle Max
[ Inserting solid conductors via push-in terminal ]
Insertion
Wire insertion
Figure 8. Wire insertion.
Figure 9. Wire separation from the connector.
Wire separation from the connector
1 Push
2
Pu
ll-o
ut
Wire distance for remote mounting
It is recommended to keep the wire distance from
sensor to Philips Xitanium SR LED driver less than
50 feet and meet the wire gauge requirement to
guarantee the performance.