DUS360CR / DUS360CR-DA
To reduce the risk of device failure, do not expose this device to rain or moisture. Installation, programming and maintenance must be
carried out by qualified personnel. All local wiring and electrical regulations must be followed when installing device.
Low profile 360° ceiling sensor
Read Instructions
– We recommend that you read these
instructions prior to commencement of installation.
Check Connections
– Ensure that all wiring terminals are securely
connected.
Mounting Location
– For indoor use only. Select sensor locations
as per user requirements. Note that the optimal locations for PIR
and PE use may be different, requiring multiple sensors in the
same area. This device is suitable for plenum use.
Data Cable
– Use screened, stranded RS-485 data cable with four
twisted pairs. Segregate from mains cables by at least 300mm.
Connect devices in a ‘daisy chain’ configuration. A data cable that
is connected to an energized device is live. Do not cut or terminate
live data cables.
Power supply
– This device must be powered by a certified class
2 energy limited source for North America, or SELV for EU regions.
Installation
– Installation must be done in accordance to the local
wiring code (or wiring rules). Installation of the home and building
automation and control system shall comply with HD60364-4-
41. The temperature limits and current-carrying capacities of
the communication wires specified in HD 384.5.523 shall not be
exceeded. Network Topology for installation is Daisy Chain.
Lens Pattern
Dimensions
Hardware
Light level
sensor
- Network sign-on button
- IR receiver
- Red LED indicator
120º PIR shield
PIR sensor
8m
6m
0
1
2
3
4
1
2
3
4
0
1
1
2
2
3
3
WARNING
This is a SELV (Safety Extra Low Voltage) device and
must be isolated and segregated from mains and other
wiring as per the local wiring rules
To reduce the risk of device failure and to avoid damage to the unit, disconnect
network and device power before installation or servicing. It is recommended that
an electrician perform this installation.
Do not expose this device to rain or moisture. Connect the cable shield to the
provided shield termination on the device connection port. If no shield termination
is provided on the device, connect the cable shield to the equipment grounding
conductor of the supplying branch circuit(s). Installation, programming and
maintenance must be carried out by qualified personnel.