DVP3680
PRODUCT SPEC
Sheet-190
Page 7 of 8
Rev.1.0
Screen saver
-
20
+/-30%
After push / disc stop
Power off –stand by
-
20
+/-30%-
After Screen saver functional
IR remote
Condition Typical Limit
Max. operating
<= +/- 45
。
- 5
(M)
(degree) <= +/- 30
。
- 7
(M)
0
。
- 10
(M)
Quiescent Current
-
<1uA
Operating Voltage
2.3 - 3.5V
Operating Current
9 – 16mA
Carrier Frequency
36KHz
+/-
2%
Battery Storage Time
?
Year
Temperature:
Battery Life Time
After 20 hours continuous sending (2s/time), IR power should be at least 20
μ
W/cm
2
Audio/ Video Characteristic Testing discs
Manufacturer
Disc name
1) TOSHIBA
TSD-4
2) DOLBY
Test disc
3) ABEX
TDV-540A
4) SONY
Test CD Type 4
12.
Playability Requirement (See attached in last page).
DISC Playability (details refer to Playability Test Plan)
DVD Video playability
Condition Typical
Limit
1. Scratch
-
- <=1.6
ABEX TDV-541
2. Black dot
-
- NA
ABEX TDV-545
3. Fingerprint
-
- NA
ABEX TDV-545
4. Non-Centre
-
- NA
ABEX TDV-552
5. Vertical deviation disc
-
- NA
ABEX TDV-562
DVD+ RW Video playability
Condition Typical Limit
Normal playback
OK
Philips HAC11
Black dot
0.8
Philips HAC11
Fingerprint
OK
Philips HAC11
Philips marginal DVD-9
OK
Philips LVP12.01 – layer 0
Philips LVP12.02 – Layer 1
CD playability
Condition Typical
Limit
Abex-TCD732RA(VDD) Track
15
OK
Abex-TCD713(ECC 210um)
NA
Power On / Off Disturbances
> -52 dB suppression of the disturbance with regard to the rated output voltage.
The peak level has to be measured according to IEC 60651 weighted (A) curve.