5-9
Remote reception is insensitive or fails.
No
Remote reception is
insensitive or fails.
Check if the remote
control works properly.
Check battery
Check R315.
Use an oscilloscope to check if there is
output waveform from the first pin IR of the
remote censor after pressing button on the
remote control.
Check the PIN 11 RC waveform
of IC1 on the remote PCB
Check if there is IR
signal on pin 109 of U1
Check if the power supply
voltage to the remote censor
is normal are normal.
Go
No
No
No
Yes
Yes
Yes
Correct connection
Yes
Change U1
IR waveform
Trouble shooting chart