1-5-1
E9H90PFS
PREPARATION FOR SERVICING
How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start
and End Sensors on this equipment. Carefully read
and follow the instructions below. Otherwise the unit
may operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into
the Deck Mechanism Assembly. Make sure the power
is on, connect TP502 (S-INH) to GND. This will stop
the function of Tape Start Sensor, Tape End Sensor
and Reel Sensors. (If these TPs are connected before
plugging in the unit, the function of the sensors will
stay valid.) See Fig. 1.
Note: Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the
tape to avoid tape damage.
Q1504
Q1503
TP502
S-INH
Fig. 1
Summary of Contents for DVDR3545V/37
Page 14: ...1 6 1 E9H90IB OPERATING CONTROLS AND FUNCTIONS ...
Page 15: ...1 6 2 E9H90IB ...
Page 16: ...1 6 3 E9H90IB ...
Page 17: ...1 6 4 E9H90IB ...
Page 71: ...DVD Main 6 7 Schematic Diagram E9H90SCD6 1 13 30 SMD ...
Page 73: ...DVD Main CBA Top View BE7H70G04022 1 13 32 ...
Page 74: ...DVD Main CBA Bottom View BE7H70G04022 1 13 33 ...
Page 75: ...DTV Module 1 2 Schematic Diagram E9H90SCDTV1 1 13 34 SMD ...
Page 76: ...DTV Module 2 2 Schematic Diagram E9H90SCDTV2 1 13 35 SMD ...
Page 77: ...DTV Module CBA Top View BE7C40G04021 1 13 36 DTV Module CBA Bottom View ...
Page 83: ...1 16 3 R4NTI Push close 0 08 V 0 02 s Push Close detection Threshold level ...
Page 122: ...2 4 9 H9820DA 43 41 42 Slide Plate L 13 S 11 Fig DM16 44 45 Slide Fig DM17 ...