1-4-1
H9330PFS
PREPARATION FOR SERVICING
How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start
and End Sensors on this equipment. Carefully read
and follow the instructions below. Otherwise the unit
may operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into
the Deck Mechanism Assembly. Make sure the power
is on, TP501 (SENSOR INHIBITION) to GND. This will
stop the function of Tape Start Sensor, Tape End Sen-
sor and Reel Sensors. (If these TPs are connected
before plugging in the unit, the function of the sensors
will stay valid.) See Fig. 1.
Note:
Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the
tape to avoid tape damage.
About REC-Safety Switch
Caution:
The REC-Safety Switch is directly mounted on the
Main CBA. When the Deck Mechanism Assembly is
removed from the Main CBA for servicing, this switch
does not work automatically.
What to do for preparation
In order to record, press the Rec button while pushing
REC-SAFETY SW on the Main CBA. See Fig. 1.
(REC-SAFETY SW)
SW506
Q504
TP501
S-INH
Q503
Fig. 1
Summary of Contents for DVD740VR
Page 10: ...1 5 1 H9330IB OPERATING CONTROLS AND FUNCTIONS DVD740VR 001 ...
Page 11: ...1 5 2 H9330IB ...
Page 12: ...1 5 3 H9330IB ...
Page 13: ...1 5 4 H9330IB ...
Page 14: ...1 5 5 H9330IB ...
Page 15: ...1 5 6 H9330IB DVD740VR 051 ...
Page 16: ...1 5 7 H9330IB ...
Page 17: ...1 5 8 H9330IB ...
Page 18: ...1 5 9 H9330IB ...
Page 19: ...1 5 10 H9330IB ...
Page 91: ...2 4 6 HC460DA S 12 19 Cap Belt Fig DM11 Fig DM12 20 C 1 21 ...