ClearScape LED

                                              

CSFS Small and CSFM Medium  

  

 

 Floodlight

 

 

YK - Yoke Mount

   

 

 

  

INSTALLATION INSTRUCTIONS 

STEP 1:   
Mount yoke to surface with (2)- 

1/2” bolts provided by others. 

  
STEP 2:   
Route the supplied cord to electrical junction box provided by 

installer. Secure cord with connector.  
 
STEP 3:   
Make electrical connections per Electrical Connection section 

inside junction box.    
 
NOTE: Electrical Connections can be made after installation 

is finished.  
  
STEP 4: Replace junction box gasket and cover. 

YK - Yoke Angle Adjustment

  

 

 

  

NOTE: Angle adjustment can be made before luminaire 

installation.  
STEP 1:  
After the luminaire is installed, the vertical angle of the 

luminaire can be adjusted up or down  
 
STEP 2:  
To adjust the angle, loosen the (2) 1/2

–13 X 1.25” 

socket head cap bolts located in yoke arm. (Do remove 

bolts.) Loosen only enough to allow rotation. 
 
STEP 3:  
Using the degree indicators, shown as a guide, rotate 

the luminaire to the desired position and retighten the 

bolt loosened in Step 2 to 75 ft.-lbs.

 

 

Adjustment Bolt and 
aiming indicator lines 

Summary of Contents for ClearScape LED Series

Page 1: ...sure you have received the correct material SF Slip Fitter Mount Note Tenon must be 3 75 or longer 2 Splice Cover Screws Splice Cover Screws INSTALLATION INSTRUCTIONS STEP 1 Remove 2 splice cover screws and splice cover To access wire splice area STEP 2 Route the supply wire through the tenon Secure the supply wire to keep from sliding back down the pole Route wire through slip fitter arm into spl...

Page 2: ...nections per Electrical Connection section inside splice area When complete replace splice cover and 2 screws removed in Step 1 Insure that gasket is correctly in place before tightening splice cover and screws SF Slip Fitter Angle Adjustment ANGLE ADJUSTMENT NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the angle of the luminaire can be ad...

Page 3: ...e junction box NOTE Electrical Connections can be made after installation is finished STEP 4 Replace junction box gasket and cover YK Yoke Angle Adjustment NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the vertical angle of the luminaire can be adjusted up or down STEP 2 To adjust the angle loosen the 2 1 2 13 X 1 25 socket head cap bolts l...

Page 4: ...ke Mount Cont d OK to mount floodlight down on yoke mount Align aiming mark with correct degree marks on bracket Note Dimensions not to scale For dimensional purposes only Opening Glass Door Frame Note Procedure to open glass door frame is the same on slip fitter and yoke mount fixtures STEP 1 Loosen two captive screws on either side of top rear floodlight cast housing STEP 2 Rotate glass door fra...

Reviews: