Caution!
–
For cooling purposes the lamp is open. When removing the
lamp do not tilt. If the inner tube is broken glass particles may
fall out.
–
Be very careful. The lamp and lampholder may still be too hot
to touch.
–
Keep lamp holder opening to your right. Do not touch lamp or
point lamp holder opening at anyone.
–
A high-pressure lamp may break if handled improperly.
8.
Carefully remove the new lamp housing from its package. Do
not touch lamp or point lamp housing opening at anyone. Do
not drop, as the impact may cause the lamp to break.
9.
Place the lamp holder in the guiding slots and insert into the
lamp compartment.
10.
Tighten the screws.
11.
Replace the cover and tighten the screws.
12.
Plug the projector back in by inserting the mains lead in the
Power socket.
13.
Press the Stand by On button to switch on the projector.
14.
Reset the lamp life time (see ‘Resetting the lamplife time’).
15.
Properly dispose of the old lamp.
Notes:
–
When replacing the lamp, always use the same type of lamp
LCA3111/00, 12NC 8670 931 11009).
–
Please dispose of lamp in special chemical disposal bins.
Resetting the lamplife time
1.
Press Menu.
–
The menu bar appears on the screen.
2.
Use cursor control to
select Settings in the
menu bar.
3.
Use cursor control to
select Lamp counter in
the sub menu.
4.
Press OK (
–/– –
) for 3 seconds to reset the lamp counter.
5.
If required, select another item you wish to adjust or press
Menu to exit.
Display
Language
Keystone correction
Start-up screen
Feedback
Lamp counter
Key lock
Factory reset
Lamp counter
0 hours
Lamp counter shows the operating hours of the
lamp. It is suggested to reset when a new lamp is
inserted. To reset keep confirmation key pressed
for 3 seconds.
Picture
Audio
Settings
Settings
Display
Language
Keystone correction
Start-up screen
Feedback
Lamp counter
Key lock
Factory reset
Picture
Audio
FIL
TE
R
FIL
TE
R
9. Maintenance
22