Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • H1111
Calculite
®
HID Surface Cylinder
C4CIN
Page 2 of 4
T4.5 Ceramic Metal Halide, Inno
250
125
375
500
30°
60°
500
250
750
1,000
30°
60°
20W T4.5
G.E. Ceramic MH, Lumen Rating = 1700 LMS., Aromat 20W Electronic Ballast
ANGLE
MEAN CP
LUMENS
0
492
5
487
46
10
472
15
441
124
20
392
25
331
153
30
268
35
198
125
40
129
45
86
71
50
66
55
59
54
60
56
65
52
52
70
48
75
43
45
80
37
85
32
35
90
26
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
322
19
45.83
0-40
447
26.33
63.51
0-60
572
33.68
81.25
0-90
704
41.45
100
40-90
257
15.12
36.49
60-90
132
7.77
18.75
90-180
0
0
0
0-180
704
41.45
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
6702
55
5702
65
6829
75
9096
85
20303
** EFFICIENCY = 41.5% **
CERTIFIED TEST REPORT NO. 2615FR DATE: MAY 7, 2004
SC..9
COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.49 .49 .49 .49
.48 .48
.46 .46
.44 .44
.41
1
.46 .44 .42 .41
.43 .40
.41 .39
.40 .38
.36
2
.42 .40 .37 .35
.39 .35
.37 .34
.36 .33
.32
3
.40 .36 .33 .31
.35 .31
.34 .30
.33 .30
.29
4
.37 .33 .30 .28
.33 .28
.32 .28
.31 .27
.26
5
.35 .31 .28 .25
.30 .25
.29 .25
.29 .25
.24
6
.33 .29 .25 .23
.28 .23
.27 .23
.27 .23
.22
7
.31 .26 .23 .21
.26 .21
.26 .21
.25 .21
.20
8
.29 .25 .22 .20
.24 .20
.24 .20
.23 .19
.19
9
.28 .23 .20 .18
.23 .18
.22 .18
.22 .18
.17
10
.26 .22 .19 .17
.21 .17
.21 .17
.21 .17
.16
LUMINAIRE INPUT WATTS = 23
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
39W T4.5
Philips Ceramic MH, Lumen Rating = 3300 LMS., Aromat 39W Electronic Ballast
ANGLE
MEAN CP
LUMENS
0
1018
5
1007
96
10
974
15
905
254
20
801
25
678
313
30
549
35
404
254
40
262
45
174
144
50
133
55
121
110
60
114
65
107
106
70
98
75
87
92
80
77
85
66
72
90
54
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
662
20.09
46.03
0-40
916
27.79
63.67
0-60
1170
35.47
81.28
0-90
1440
43.64
100
40-90
523
15.85
36.33
60-90
269
8.17
18.72
90-180
0
0
0
0-180
1440
43.64
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
13544
55
11586
65
13906
75
18535
85
41710
** EFFICIENCY = 43.6% **
CERTIFIED TEST REPORT NO. 2614FR DATE: MAY 5, 2004
SC = .9
COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.52 .52 .52 .52
.51 .51
.48 .48
.46 .46
.44
1
.48 .46 .44 .43
.45 .42
.43 .41
.42 .40
.38
2
.45 .42 .39 .37
.41 .37
.39 .36
.38 .35
.33
3
.42 .38 .35 .33
.37 .32
.36 .32
.35 .31
.30
4
.39 .35 .32 .30
.35 .29
.33 .29
.33 .29
.27
5
.37 .32 .29 .27
.32 .27
.31 .26
.30 .26
.25
6
.35 .30 .27 .25
.30 .24
.29 .24
.28 .24
.23
7
.33 .28 .25 .23
.28 .22
.27 .22
.26 .22
.21
8
.31 .26 .23 .21
.26 .21
.25 .21
.25 .20
.20
9
.29 .24 .21 .19
.24 .19
.24 .19
.23 .19
.18
10
.28 .23 .20 .18
.22 .18
.22 .18
.22 .18
.17
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%