Calculite

®

 CFL Open Downlight

  8091CB

Page 1 of 2 

6" Aperture Triple Tube Cross Blade Louver

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

Reflector Trim

Frame-In Kit

8091CBW

 

White Cone, White Flange

8091CBA

 

Aluminum Cone, White Flange

S6132BU   

6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam)

Dimming Options:
S6132B

 

 

CU3

 

Lightolier PowerSpec 3% Dimming (120/277V)  

J1LD3

 Lutron 5% Dimming (120V)

J2LD3

 

Lutron 5% Dimming (277V) 

 

JUM7

 Mark 7 Dimming (120/277V)

J1MX

 

Mark 10 Dimming (120V) 

 

J2MX

 Mark 10 Dimming (277V)

Other dimming product available, please consult factory

Remodeler Frame-In Kits

6126BURM

    6" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)

6132BURM

  6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam)

Features

1.  Reflector:

 16 ga. Die-formed aluminum, Anobrite

®

 finish.

2.  Socket Cup:

 Effectively dissipates heat and positions lamp holder. 

Snaps onto reflector neck to assure consistently correct optical alignment 
without tools.

3.  Mounting Frame:

 Galvanized steel for dry or plaster ceilings. Accepts other 

6” Triple Tube reflectors (see S6132BU Spec Sheet).

4.  Retaining Springs:

 Precision-tooled steel friction springs secure reflector to 

mounting frame for quick, tool-less installation.

5.  Mounting Brackets:

 16 ga. steel. Adjust from inside of fixture. Use 3/4" or 

1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.

6.  Ballast/J-Box:

 Electronic 120V-277V. UL listed for through branch circuit 

wiring with max of (8) No. 12AWG, 90°c supply conductors. Outboard-
mounted to reduce heat transfer and maintain lamp efficacy and life.  
Service from below without tools.

7.  Cross Blade Louver:

 Die-formed, 16 ga. aluminum, matte white or painted 

aluminum finish. Accepts lens (consult factory). 50° cutoff to lamp, medium 
beam. Keyed for orientation.

Electrical

Note:

 For ballast electrical data and latest lamp/ballast compatibility refer to 

“Ballast”

 specification sheet for complete electrical data.

UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90
degree C supply conductors.

Options and Accessories

Other Louver Finishes 

Consult Factory

Emergency   

Add suffix 

EM*

Chicago Plenum 

Use 6132BULC

Existing/Thk. Ceiling 

FA EC6*

Emergency Ltg. Kit 

FA EM3E*

Fuse (Slow Blow)  

Add Suffix 

F

*See Spec. Sheets: FAEC, FAEM 

Mounting Bars & Accessories; see Specification Sheet MBA. 
Sloped Ceiling Adapters; see Specification Sheet SCA.
IC Frame available; see 

C6CFL32

 specification sheet.

Labels

UL listed for damp locations.

7

2

3

4

5

6

6"

(152 mm)

5-7/8""  (149 mm)  Dia. 

7-1/4" Self-Flanged 

Trim (184 mm)

1" (25 mm) min.-

2-1/8" (54 mm) max.

1-1/8" (29 mm) max.

Ceiling Thickness

3"

(76 mm)

1

Top View

13-7/8"

(353 mm)

11-1/8"

(283 mm)

10"

(254 mm)

4 5/8"

(117mm)

10"

(254mm)

12 3/4"

(324mm)