background image

Warnings, Cautions and Operating Instructions
WARNING:

These lamps must be operated in fixtures

designed for use with High Pressure Sodium lamps.The
fixture wattage rating must match the wattage indicated
on the outer glass bulb. Do not scratch the outer bulb or
subject it to pressure as this could cause the outer bulb to
crack or shatter. A partial vacuum in the outer bulb may
cause glass to fly if the glass is struck. Operating the lamp
improperly may result in

PERSONAL INJURY,

PROPERTY DAMAGE, BURNS AND FIRE.

1. If the outer glass bulb is broken, shut off power

immediately and remove the lamp after it has cooled.

2. Use only auxiliary equipment meeting Philips and/or

ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers

electrical data.

3. Protect lamp base, socket and wiring against moisture,

corrosive atmospheres and excessive heat.

4. Replace the lamp if the outer glass bulb has been

scratched, cracked or damaged in any way.

5. If a lamp bulb support is used, be sure to insulate the

support electrically so as to avoid possible decomposi-
tion of the bulb glass.

6. Do not use this lamp in a fixture which redirects a

substantial portion of the energy toward the arc tube
and its immediate vicinity, as this may lead to very early
lamp failure.

7. Take care in handling and disposing of lamps. If arc tube

is broken, avoid skin contact with any of the contents
or fragments.

8. The arc tube of this lamp contains sodium and mercury.

Dispose of in accordance with federal, state and
local requirements.

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Basic High Pressure Sodium Lamps

1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least

50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For HPS lamps with a rated average life of 18,000 hours, life is based on survival of 67% of the lamps.

2) Measured at 100 hours of life in vertical operating position.

3) Approximate mean lumen output at 40% of lamp rated average life. Measured in vertical operating position.
4) Approximate color temperature in Kelvin degrees.

Above specifications subject to change without notice.

Philips Basic High Pressure Sodium (HPS) Lamps

Ordering, Electrical and Technical Data

© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 4/08

P-5921

www. philips.com

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050

A Division of Philips Electronics Ltd.

Rated

Approx.

Approx.

Color

Product

Pkg

Bulb

ANSI

MOL

LCL

Avg. Life

Initial

Mean

Temp.

Number

Description

Watts

Qty

Bulb

Finish

Base

Code

(In.)

(In.)

(Hrs.)

1

Lumens

2

Lumens

3

(K)

4

15243-9

C70S62/BASIC HPS

70

12

T-14

Clear

Mogul

S62

7

3

4

5

18,000

6000

4500

2100

15244-7

C100S54/BASIC HPS

100

12

T-14

Clear

Mogul

S54

7

3

4

5

18,000

9000

6750

2100

15245-4

C150S55/BASIC HPS

150

12

T-14

Clear

Mogul

S55

7

3

4

5

18,000

15,000

11,250

2100

15246-2

C250S50/BASIC HPS

250

12

T-14

Clear

Mogul

S50

9

3

4

5

3

4

18,000

25,500

19,125

2100

15247-0

C400S51/BASIC HPS

400

12

T-14

Clear

Mogul

S51

9

3

4

5

3

4

18,000

47,500

35,625

2100

Summary of Contents for Basic HID Lamp

Page 1: ...sic High Intensity Discharge Lamps are an alternative option to Standard Metal Halide Protected Metal Halide and High Pressure Sodium lamps Basic Metal Halide Lamps Available in 175W 250W 400W and 1000W Basic Protected Metal Halide Lamps Available in 175W 250W 400W and 1000W Basic High Pressure Sodium Lamps T 15 bulb shape Available in 70W 100W 150W 250W and 400W ...

Page 2: ...NS AND FIRE Certain lamps that will retain all the glass particles should inner arc tube rupture occur are commercially available from Philips Lighting Company RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture CAUTION TO REDUCETHE RISK OF PERSONAL INJURY PROPERTY DAMAGE BURNS AND FIR...

Page 3: ...STRUCTIONS 1 RELAMP FIXTURES AT OR BEFORETHE END OF RATED LIFE Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture 2 Before lamp installation replacement shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards 3 Use only auxiliary equipment meeting Philips and or ANSI standards Use within...

Page 4: ...GS CAUTIONS AND OPERATING INSTRUCTIONS for Basic High Pressure Sodium Lamps 1 Rated average life is the life obtained on the average from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start It is based on survival of at least 50 of the lamps and allows for individual lamps or groups of lamps to vary considerably from the aver...

Reviews: