Ordering Data
Product
Pkg.
Number
Ordering Code
Qty.
Beam
MBCP
2
14477-4
CDM-i25W/830/PAR38/10/ALTO
6
Spot (10˚)
26,000
14478-2
CDM-i25W/830/PAR38/25/ALTO
6
Flood (25˚)
5600
14479-0
CDM-i25W/830/PAR38/40/ALTO
6
Wide Flood (40˚)
2100
Warnings, Cautions and Operating Instructions
WARNING:
These lamps can cause serious skin burn
and eye inflammation from short wave ultraviolet radiation
if outer envelope of the lamp is broken or punctured. Do
not use where people will remain for more than a few
minutes unless adequate shielding or other safety precautions
are used. Certain lamps that will automatically extinguish
when the outer envelope is broken or punctured are
commercially available.” This lamp complies with FDA
radiation performance standard 21 CFR subchapter J.
(USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at
once and replace the lamp to avoid possible injury
from hazardous short wave ultraviolet radiation. Do
not scratch the outer bulb or subject it to pressure
as this could cause the outer bulb to crack or shatter.
A partial vacuum in the outer bulb may cause glass
to fly if the envelope is struck.
WARNING:
The arc-tube of metal halide lamps are designed
to operate under high pressure and at temperatures up to
1000°C and can unexpectedly rupture due to internal or
external factors such as a ballast failure or misapplication.
If the arc-tube ruptures for any reason, the outer bulb may
break and pieces of extremely hot glass might be discharged
into the surrounding environment. If such a rupture were to
happen,
THERE IS A RISK OF PERSONAL INJURY,
PROPERTY DAMAGE, BURNS AND FIRE.
This lamp contains an arc tube with a filling gas
containing less than 41 nCi of Kr-85 and is distributed
by Philips Lighting Company, a division of Philips
Electronics North America Corporation, Somerset,
New Jersey, 08875.
CAUTION:
TO REDUCE THE RISK OF PERSONAL INJURY,
PROPERTY DAMAGE, BURNS AND FIRE RESULTING
FROM AN ARC-TUBE RUPTURE THE FOLLOWING
LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED.
LAMP OPERATING INSTRUCTIONS:
1. At high lighting levels or when illuminating light-sensitive
materials the use of an extra UV filter is recommended.
2. Before lamp installation/replacement, shut power off and
allow lamp and fixture to cool to avoid electrical shock and
potential burn hazards.
3.Time should be allowed for lamps to stabilize in color
when turned on for the first time.This may require several
hours of operation, with more than one start. Lamp color
is also subject to change under conditions of excess
vibration or shock, and color appearance may vary
between individual lamps.
4. Lamps may require up to 10 minutes to re-light if there
is a power interruption.
5. Do not operate with an additional ballast, since a ballast
is integrated in the lamp itself.
6. Do not use in totally enclosed recessed fixtures.
7. Take care in handling and disposing of lamps. If an
arc tube is broken, avoid skin contact with any of the
contents or fragments.
8. Lamp should not be used with dimmers.
9. Protect lamp, lamp socket and wiring against moisture,
corrosive atmosphere and excessive heat. Lamp should
be used in dry locations only.
These lamps may be used in open fixtures.
Hg: LAMP CONTAINS MERCURY Manage
in Accord with Disposal Laws See:
www.lamprecycle.org or 1-800-555-0050
1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests
under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the
lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
2) Maximum Beam Candlepower.
3) CAUTION: New construction should allow for the current used by these lamps. Because of a power factor
of 0.57 in the ballast of the lamp, the lamp uses .36 amps.
4) Measured at 100 hrs. life. Approximate lumen values listed are for vertical operation of the lamp.
5) Approximate lumen output at 40% of lamp rated average life.
This product utilizes ALTO
®
Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching
Procedure (TCLP) and can be classified as non-hazardous waste. Check with state and local regulations.
Above specifications subject to change without notice.
© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 12/08
P-5747-F
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Electrical and Technical Data
Wattage ––––––––––––––––––––––––––––––––25W
Input Voltage ––––––––––––––––––––––––120V±10%
Max.THD –––––––––––––––––––––––––––––––142%
Frequency–––––––––––––––––––––––––––––––60Hz
Input Current
3
––––––––––––––––––––––––––––0.36
Warm-up to 80% Full Brightness –––––––––2 minutes
Restrike Time for Hot Lamps–––––––––– 5-7 minutes
Minimum Operating Temp.–––––––––––– -20˚C (-4˚F)
Physical Characteristics
Bulb Size–––––––––––––––––––––––––––––––PAR38
Bulb Finish ––––––––––––––––––––––––––––––Clear
Base –––––––––––––––––––––––––––––––––Medium
Max. Overall Length (MOL) –––––––––5.33'' (135mm)
Light Center Length (LCL) ––––––––––––––––––N/A
Arc Length –––––––––––––––––––––––––––––––N/A
Arc Tube Material ––––––––––Polycrystalline Alumina
Max. Ring Temp. ––––––––––––––––––––65ºC (149ºF)
Max. Cap Temp. ––––––––––––––––––––65ºC (149ºF)
Max. Neck Temp. –––––––––––––––––––80˚C (176˚F)
Max.Arc Tube to Base Eccentricity ––––––––––––––3º
Operating Characteristics
Approx. Initial Lumens
4
–––––––––––––––––––––1275
Approx. Mean Lumens
4,5
–––––––––––––––––––––880
Rated Average Life, Hours.
1
––––––––––––––––15,000
Correlated Color Temp. (CCT)
2
––––––––––––3000K
CIE Chromaticity Approx.
2
–––––––––––x-.440, y-.393
Color Rendering Index (CRI)––––––––––––––––––87
Efficacy (lpw)–––––––––––––––––––––––––––––––51
Beam Angle (at 50% of MBCP)––––––––––10˚/25˚/40˚
Operating Position
Universal-Open or Enclosed PAR Style Luminaires
(Do not use in totally enclosed recessed luminaires.)
Spectral Power Distribution
Po
w
er
(W
pe
r
nm
)
200
300
400
500
600
700
800
Wavelength (Nanometers)
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0