background image

23

PH

ILIPS MED

IC

A

L

 SYS

T

EMS

SPECIFICATIONS

AED TRAINER 3

Size

8.6” x 5.2” x 2.2” (218 mm x 133 mm x 57 mm)

Weight 

 

(with batteries)

1.3 lb (600 g)

Battery type and 
quantity

4 AA size alkaline batteries (LR6)

Battery capacity

> 10 hours

Environmental 
specifications

Operating temperature: 50º - 95º F (10º - 35º C)
Storage temperature: 32º - 104º F (0º - 40º C)
Relative humidity: 0 - 90% non-condensing

Material

Housing: Acrylonitrile butadiene styrene (ABS)
Control buttons: Silicone
Foot: Polyurethane (PU)

CARRY CASE

Size

14.3” x 11.2” x 5.2” (362 x 290 x 132 mm)

Weight

10.5 oz (300 g)

Material

Nylon

REMOTE CONTROL

Size

3.8” x 2.1” x 0.2.” (96 mm x 54 mm x 6 mm)

Battery type

Lithium CR2025 3V

TRAINING INFANT/CHILD KEY

Size

1.8” x 1.0” x 0.3” (48 x 25 x 7 mm)

Material

Polycarbonate and polybutylene terephthalate 

 

(PC + PBT)

Summary of Contents for Aed Trainer 3

Page 1: ...861467 Edition 2 A E D T r a i n e r 3 I N S T R U C T I O N S F O R U S E 453564382981 ...

Page 2: ...lashes when device is receiving commands from the remote control stays off when the device is not in use G Infant Child Key Port Receptacle for the Training Infant Child Key When Key is inserted the AED Trainer 3 operates in Infant Child mode to simulate defibrillation of an infant or child under 8 years old or 25 kg 55 lbs H Green On Off Button Turns on the AED Trainer 3 and starts voice instruct...

Page 3: ...P H I L I P S M E DI C A L S Y S TE M S AED Trainer 3 861467 Edition 2 I N S T R U C T I O N S F O R U S E ...

Page 4: ... your local Philips representative for information on revisions Edition history Edition 2 Publication date February 2013 Publication number 453564382981 Copyright 2013 Laerdal Medical AS All Rights Reserved Device Manufacturer Laerdal Medical AS Tanke Svilandsgate 30 N 4002 Stavanger Norway For Technical Support If you need technical support please contact your local Philips representative or go t...

Page 5: ...ies 4 Selecting a Language 5 Changing the Configuration 6 Connecting the Training Pads 7 Accessing the Training Infant Child Key 9 USING THE AED TRAINER 3 Preparing to use the AED Trainer 3 10 Selecting a training scenario 11 Running a Training Scenario 12 Using the Optional Remote Control 12 APPENDICES Parameter Settings 15 Training Scenarios 17 Remote Control 19 Troubleshooting Tips 21 Specifica...

Page 6: ...P H I L I P S M E D I C A L S Y S TE M S INTENTIONALLY BLANK ...

Page 7: ...ed with a factory default setup that complies with the ERC European Resuscitation Council and AHA American Heart Association 2010 Guidelines The device may also be configured to conform to local protocols or Guideline Updates NOTE Before using the HeartStart FR3 Defibrillator the responder should have completed an appropriate responder training program which may include the use of the AED Trainer ...

Page 8: ...rompts as the FR3 AED Extensive configurability Like the FR3 AED the AED Trainer 3 configuration can be customized and its operation easily updated as needed NOTE The Training Infant Child Key cannot be used with the HeartStart FR3 AED An FR3 Infant Child Key is required for use with the AED HOW SUPPLIED STANDARD PACKAGE CONTENTS The AED Trainer 3 is shipped with the following items as standard on...

Page 9: ...ner 3 Remote Control with one replaceable lithium CR2025 3V battery REF 989803171631 Replacement HeartStart Training Pads III Interconnect Cable REF 989803150201 Replacement HeartStart Training Pads III REF 989803150181 Replacement External Manikin Adapters set of 5 REF M5089A Laerdal LINK Technology Training Pads REF M3755A for use with compatible Laerdal manikins TRAINING TRAINING Carry Case Phi...

Page 10: ...stem Card follow the steps below 1 Squeeze the latch on the battery compartment lid to release the lid Lift out the lid and set it aside 2 Check that the Operating System Card is installed in the slot at the top of the compartment If not install the Operating System Card in the orientation shown INSTALLING THE BATTERIES The AED Trainer 3 requires four AA size alkaline batteries not included To ins...

Page 11: ...English 2 Release both buttons 3 Press and hold the orange Shock button to scroll through each available language The AED Trainer 3 announces each new language 4 When the desired language is announced press the green On Off button to turn off the AED Trainer 3 and store the selected language The AED Trainer 3 will use this language when it is next turned on 5 Apply the appropriate Training Only st...

Page 12: ...partment 3 Insert the Operating System Card into the card slot of your computer or if no slot is available install the card into a standard card reader and connect it to your computer 4 Open the AED Trainer 3 Configuration program Aedt3Cfg exe and select the desired language for use during configuration 5 Click Open and go to the drive with Operating System Card 6 Click on System and then on Confi...

Page 13: ...he AED Trainer 3 See page 4 for directions on installing the card The AED Trainer 3 configuration will be updated automatically the next time the AED Trainer 3 is turned on CONNECTING THE TRAINING PADS The AED Trainer 3 may be used with either HeartStart Training Pads III or Laerdal LINK Technology Training Pads HEARTSTART TRAINING PADS III To connect the HeartStart Training Pads III to the AED Tr...

Page 14: ... carry case The case is designed to store the AED Trainer 3 with the pads pre connected The HeartStart Training Pads III are designed for up to 100 uses To help ensure continued performance avoid leaving the pads in heat or direct sunlight To replace the pads disconnect the connector plug from the AED Trainer 3 and repeat Steps 1 through 3 above LAERDAL LINK TECHNOLOGY TRAINING PADS To connect the...

Page 15: ...n the carry case The case is designed to store the AED Trainer 3 with the pads pre connected ACCESSING THE TRAINING INFANT CHILD KEY The Training Infant Child Key is supplied on a tether pre installed in the AED Trainer 3 carry case To access the Training Infant Child Key for use remove it from its compartment in the case lid and extend the tether to insert the Key into the Infant Child Key port o...

Page 16: ...ore turning on the AED Trainer 3 follow the steps below 1 Check that the pads are pre connected as described on page 7 If no training pads are connected when the AED Trainer 3 is turned on the AED Trainer 3 will provide a voice instruction to place the pads on the patient s bare chest and then plug in the pads connector by the flashing light 2 If you are using HeartStart Training Pads III attach t...

Page 17: ...ed on the diagram on the inside front cover of this manual The infant child mode is intended for training in defibrillation of an infant or child under 8 years old or 55 lbs 25 kg SELECTING A TRAINING SCENARIO When you are ready to use the AED Trainer 3 follow the steps below 1 Press and hold the green On Off button for approximately six seconds The AED Trainer 3 will instruct you to press the ora...

Page 18: ...or ten minutes RUNNING A TRAINING SCENARIO To run a training scenario press the On Off button to turn on the AED Trainer 3 and following the AED Trainer 3 s voice instructions to simulate use of the FR3 AED in an emergency For troubleshooting assistance see page 21 USING THE OPTIONAL REMOTE CONTROL If desired the AED Trainer 3 can be used with an optional remote control that allows the instructor ...

Page 19: ...L S Y S TE M S See page 19 for a description of the Remote Control operation NOTE The AED Trainer 3 can be configured for use with the AED Trainer 2 remote control if desired See page 6 for directions on changing the configuration ...

Page 20: ...P H I L I P S M E D I C A L S Y S TE M S 14 APPENDICES PARAMETER SETTINGS TRAINING SCENARIOS REMOTE CONTROL TROUBLESHOOTING TIPS SPECIFICATIONS REGULATORY INFORMATION GLOSSARY OF SYMBOLS ...

Page 21: ...nfinite Sets the time interval used to determine if a delivered shock should be counted as part of the current shock series This parameter applies only when the shock series setting is greater than 1 Metronome on off Enables ON and disables OFF audio beats for CPR compressions AED Trainer 2 Remote Control AEDT2 AEDT3 Enables or disables use of the AED Trainer 2 Remote Control rather than the AED T...

Page 22: ...nario 1 2 3 4 5 6 7 Sets the training scenario used when the AED Trainer 3 is turned on LINK Pads attachment tolerance Slide Scale Lower to Higher Determines the required placement accuracy of training pads on a Laerdal LINK manikin Lower tolerance equates to a more accurate pad placement requirement Manikin LED on off Enables ON or Disables OFF the automatic illumination of the electrode pad LEDs...

Page 23: ...m detected by AED Trainer 3 Pads problem detected by AED Trainer 3 CPR First protocol initiated by AED Trainer 3 SCENARIO SYMBOL DESCRIPTION 1 One shock for conversion Shockable rhythm One shock needed for conversion Non shockable rhythm 2 One shock for conversion Non shockable rhythm Shockable rhythm One shock needed for conversion Non shockable rhythm 3 Troubleshooting pads one shock for convers...

Page 24: ... needed for conversion Non shockable rhythm 5 Non shockable rhythm Non shockable rhythm throughout 6 Two shocks for conversion Shockable rhythm Two shocks needed for conversion Non shockable rhythm 7 CPR first one shock for conversion Shockable rhythm CPR First Shockable rhythm One shock needed for conversion Non shockable rhythm 8 Shockable rhythm Shockable rhythm throughout SCENARIO SYMBOL DESCR...

Page 25: ...ythm Press to initiate simulated non shockable rhythm This function overrides the running scenario CPR First Press to simulate a shockable rhythm that will generate a CPR First decision by the AED Trainer 3 for the first rhythm analysis and a shock decision for subsequent rhythm analyses This function overrides the running scenario Good Pads Connection Press to simulate good pads connection to the...

Page 26: ... in the AED Trainer 3 The AED Trainer 3 turns off and chirps every 10 seconds NOTE To clear the error condition and turn on the AED Trainer 3 for further use press the green On Off button twice AED Low Battery Press once to simulate a Low Battery condition in the AED Trainer 3 Press a second time to initiate a Replace Battery prompt Speaker Volume Press buttons to adjust AED Trainer 3 speaker volu...

Page 27: ...riginal Operating System Card Obtain replacement Operating System Card AED Trainer 3 gives Analyzing prompt before pads are applied to manikin The HeartStart Training Pads II are connected the AED Trainer 3 senses that pads are in place as soon as the pads connector plug is inserted To use HeartStart Training Pads II apply the pads to the manikin before connecting them to the AED Trainer 3 Alterna...

Page 28: ... C A L S Y S TE M S 22 AED Trainer 3 battery depletes prematurely One or more of the batteries is incorrectly oriented Reinstall batteries as illustrated inside the battery compartment ISSUE POSSIBLE CAUSE SUGGESTED ACTION ...

Page 29: ... 95º F 10º 35º C Storage temperature 32º 104º F 0º 40º C Relative humidity 0 90 non condensing Material Housing Acrylonitrile butadiene styrene ABS Control buttons Silicone Foot Polyurethane PU CARRY CASE Size 14 3 x 11 2 x 5 2 362 x 290 x 132 mm Weight 10 5 oz 300 g Material Nylon REMOTE CONTROL Size 3 8 x 2 1 x 0 2 96 mm x 54 mm x 6 mm Battery type Lithium CR2025 3V TRAINING INFANT CHILD KEY Siz...

Page 30: ...use undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ins...

Page 31: ...equirements of Directive 2004 108 EC on electromagnetic compatibility This product does not contain natural rubber latex Australian Communication Authority compliance mark Printed on recycled paper This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE LATEX N25270 ...

Page 32: ...P H I L I P S M E D I C A L S Y S TE M S INTENTIONALLY BLANK ...

Page 33: ...P H I L I P S M E DI C A L S Y S TE M S INTENTIONALLY BLANK ...

Page 34: ...n Systeme Boeblingen GmbH Cardiac and Monitoring Systems Hewlett Packard Strasse 2 71034 Boeblingen Germany 49 7031 463 2254 Latin America Philips Medical Systems Ltda Av Dr Marcos Penteado Ulhôa Rodrigues 401 Parte 16 06460 040 Barueri SP Brazil 0800 7017789 Asia Pacific Philips Electronics Hong Kong Ltd 6 F Core Building 1 1 Science Park East Avenue Hong Kong Science Park Shatin New Territories ...

Reviews: